Electrical
Rating
Volts
Hertz
Amperes
Watts
1,450
120
60
12
(max)
3/8"-
1/2"
(10mm - 13mm)
Figure 5
Electrical Preparation
.
ELECTRICAL
PREPARATION
Avoid E(ectrica( Shock Hazard
Do not work on an energized
circuit. Doing
so could result in serious
injury or death.
Only qualified
electricians
should
perform
electrical
work. Do not attempt any work on the
dishwasher
electric supply circuit until you are
certain the circuit
is de=energized.
Avoid Fire Hazard
Make sure electrical work is properly instal(ed.
Only qualified
electricians should perform
electrical work.
Electrical
Supply
The customer has the responsibility of ensuring that the
dishwasher electrical instal(ation is in compliance with
al( national and (ocal electrical codes and ordinances.
The dishwasher is designed for an electrical supply of
120V, 60 Hz, AC, connected to a dishwasher-dedicated,
properly grounded electrical circuit with a fuse or breaker
rated for 15 amps. Electrical supply conductors shal( be
a minimum #14 AWG copper wire rated at 75°C (167°F)
or higher.
Regardless of where the electrical supply cable enters
the enclosure, position the cable 21" (533mm) from the
enclosure's left side, as shown in Figure 4. Extend the
cable 30" (762mm) from the enclosure's back, as shown
in Figure 4.
Remove 3" - 4" (76mm - 102mm) of the cable's outer
casing, as shown in Figure 5, then remove 3/8"- 1/2"
(10 - 13mm) of insulation from each wire, as shown in
Figure 5.