STEP3 : PREPARE THEVENtiNG BLOWER
ROOF VENTED iNSTALLATiON
1. Remove one blower
unit mounting
screw and two
blower
plate
screws. Remove the blower
plate
from cabinet.
See Figure 18.
2. Carefully
lift the blower
unit out of the microwave
oven.
3. Rotate blower
unit 90 ° so the exhaust
ports face
the top of the cabinet.
See Figure 19.
4. Place blower
unit back into microwave
oven.
Blower
plate
unting
screws
Blower
plate
Blower
unit
mounting
screws
Figure 18
5. Use side cutters or tin snips to cut and remove
knockouts '_A'_ from blower
plate.
Discard knockouts.
Be careful
not to distort the
plate.
See Figure 20.
6. Reattach
blower
plate to microwave
oven.
Attach
with the one blower
unit mounting
screw
and then the two blower
plate
mounting
screws.
See Figure 21.
Figure 19
Blower
unit
Knockots "A"
Blower
plate
Figure 20
Blower
unit
Blower plate
-.
mo_unting
screws
Blower
plate
Blower unit
mounting
screws
Figure 21