Venting
The microwavehood is set for ventless (recirculating)
installation. Forwall or roofventing changesto the
venting system must be made.
CAUTION:
To reduce risk of fire and to
properly
exhaust
air, be sure to vent air
outside.
Do not vent exhaust air into
spaces within walls or ceilings
or into
attics, crawl spaces or garages.
Forwall or rootventing methods:
Choose between roof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearance within the wall for the exhaust vent.
Vent materials neededfor installationare not included.
Wall and roofcaps must have back-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints in the vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOT recommend:
v' flexible metal vent.
NOTE:If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexible metal elbows count twice as much as standard
elbows.
Vertical venting
Salida de aire per el cielo raso
root cap
caperuzade cielo raso
3-1/4"x 10" through-the-roof
a tray,s delcielorasoperun orificio
de3-1/4"x 10
Wall venting
Salida de alre p0r la pared
wall cap
caperuza depared
3-1/4" x 10" through-the-wall
a trav6s do la pared per on
orificio de 3-1/4" x 10
Roundvent transition
Transici6nde conducto de salida de aire redondo
roof cap __
6" min. diameter round
wail cap
cooductode salida de aire
] ,"-_'1-...
......
_/,,=n_,r,tT=
redondo de 6" de di_metro
I"
I
' "..'o--,K_,_._.C.",_,
miuimo
:_
%
u_ pa,_u
code
_
-114" x10"to 6"roundvent
transition
3" minimum height (required for
damper to fully open)
Altura minima de 3" (oecesaria
para quo la compuertase abra
completamente)
transici6n de conductode salida
de aire redondo de 3-1/4" x 10"
a 0"
Salida de aire
La campana del hornoha side disefiada para ser instalada
sin salida de aire (recirculaci6n). Para salida de aire en la
paredo en el cielo raso, deben hacersecambios en ei
sistema de salida de aire.
PRECAUCION:
para reducir el riesgo de
incendio
y para instalar el sistema
de
salida de aire adecuado,
aseg_rese
de
que el aire salga al exterior.
No ponga la
salida de aire en espacios
dentro de
paredes
o cielos rases o en _ticos,
sbtanos
de pequefia
altura o garajes.
Para m6todos de saiida de aire a trav6s de la pared o el
cielo raso:
Decida entre instalar la salida de aire a trav6s del cielo raso o
de una pared.
Si se decide por el m_todo de salida de aire a trav6s de la
pared, aseg_rese de que haya el espacio adecuado dentro de
la pared para el conducto de salida de aire.
No se incluyenlos materiales del conductode salida de aire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielo raso y pared deben tenor
compuerta de contratiro.
Recomendamos:
v' usar un conducto de salida de aire met_lico y rigido.
v" que la Iongitud del conducto de salida de aire y el n_mero
de codos se mantengan a un minimo para Iograr un
rendimiento eficiente.
v" que las dimensiones del conducto sean uniformes.
v" usar cinta para conducto para sellar todas las uniones en el
sistema de salida de aire.
v" usar masilla para calafatear para sellar la pared exterior o la
abertura en el cielo raso alrededor de la caperuza.
v" no se deben instalar dos codos juntos.
NO recomendamos:
v" conducto de salida de aire met_lico flexible
NOTA:si debe usarse un conducto met_lico flexible, calcule
cada pie de conducto met_lico flexible como si fueran dos pies
de conducto met_lico rigido. Los codos de metal flexible hacen
por dos codos est_ndar.
6
Recommendedvent length:
Use 3-1/4" X 10" rectangular or 6" round vent.
The total length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceed the
equivalent of 140 feet of 3-1/4_X 10" rectangular or 6"
diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To calculate the length of system you need,add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4" x 10" vent system:
1 - 3-1/4" x 10"
90° elbow
= 25 ft.
1 - wall cap
= 40 ft.
8 feet straight
8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6" vent system:
1 -transition
= 5 ft.
2 - 90° elbows
20 ft.
1 - wall cap
= 40 ft.
8 feet straight
8 ft.
Length of 6" system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" extension vent between
the damper assembly and adapter must be installed to
prevent damper from sticking.
Recommended standardfittings
Accesorios est;Zndar r ecomendados
3-1/4" x 10"to 6"= 5 it.
De3-1/4"x t0" a6"=
5 pies
3-1/4"x t0" roof cap= 24 ft.
Caperuza d ecielorasode
3-1/4"x 10"=24 pies
3-1/4"x 10"
90° dbow = 25ft.
Codode90° y 3-1/4' x
10"= 25 pies
90° elbow=l0 ft.
Codede90° =
10pies
3-1/4"x 10"wallca
=40 ft.
Caperuza d epared
de3-1/4"x 10"=
40 pies
45° elbow= 5 ft.
Codode45o=
5 pies
_i
iil i _'
'iliiii! iiiiiiiiiiiiiiii_,, _ eiiiiiiiill iiiiiiiii'
3-1/4"x 10"flat
eJbow = 10ft.
Codopianode3-1/4"
x 10"= 10 pies
3-1/4" x 10" vent system
Sistemade salida de aire de 3-1/4" x 10"
3-1/4" x 10"
90° elbow
Code de go° y
6 It.
3-1/4"x1_
_6pies_
p.
wallcap
Y I
I
II_ caperuza
de
' It'> pared
2_. (2 pies)
6"vent system
Sistemade salida de aire de 6"
go ° elbows
code de90 =
2
transition
traosici6o
2 ft. (2 pies)
Longitudrecomendadadel conductode salida de aire:
Use un conducto de salida de aire rectangular de 3-1/4 _x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salida de aire recto, el codo, las transiciones, las
caperuzas de pared o cielo raso no deben exceder el
equivalente a 140 pies de conducto rectangular de salida de
aire de 3-1/4"x 10" o conducto redondo de 6" de di_metro.
Para mejores resultados, no use m_s de tres codos de 90°.
Para calcular la Iongitud del sistema que necesita, agregue la
equivalencia en pies para cada pedazode conducto usado en
el sistema. Vea los siguientes ejemplos:
Sistema de salida de aire de 3-1/4" x 10":
1 -Codo de 90°
y 3-1/4" x 10"
= 25 pies
1 - Caperuzade pared
= 40 pies
8 pies recto
= 8 pies
Longitud de un
sistema de 3-1/4_'x 10" = 73 pies
Sistema de salida de aire de 6":
1 -transici6n
=
5 pies
2 - codos de 90°
20 pies
1 - caperuza de pared
= 40 pies
8 pies recto
8 pies
Longitud de un
sistema de 6"
= 73 pies
Si el actual conducto de salida de aire es redondo, debe usarse
un adaptador de rectangular a redondo y un conducto de
extension rectangular de 3" entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.