Operation Hints - Haier AS102ALARA Operation Manual

Digital dc variable frequency healthy split air conditioner
Hide thumbs Also See for AS102ALARA:
Table of Contents

Advertisement

Operation Hints

Cold Air Prevention
When heating is started, the fan in the indoor unit will
not be started immediately to prevent cold air being blew
out.
Defrost
During the heating, when the heat exchanger in the
outdoor unit is frosted, the air conditioner will defrost
automatically for a few minutes. During the defrost, the
fan in the outdoor unit does not run until the defrost is
completed.
Notes
When heating, the air conditioner takes a lot of heat
from outdoor and release the heat into the room , therefore
the outdoor temperature will affect the heating effect.
Instructions Operation
Adjust the air flow direction
Set a proper room temperature
Too cold and too hot are not only harmful for
health but also will consume too much electricity.
Best
temperature
Notes: After installation, please confirm that the refrigerant is not leaked.
Wait a moment
Avoid the direct sunlight and hot air flow
Use of Timer
Time set can make your room in a comfortable
temperature when you wake up or come back.
6
Installation
Installation of Indoor Unit
The indoor unit shall be installed as per the indoor unit
installation drawing:
1.Fix the Mounting Plate and Localize the Wall-through Hole
Fix the mounting plate as per the selected position and the piping layout (see the installation
drawing).
Fix the mounting plate on a smooth wall surface under the beam or beside a column. First fix the
mounting plate with a steel nail,then level it with a level meter or a drop line, then fix it with A4
50 cement nails.If the expansion screws are used,first drill holes into the wall( 4.8mm), then
put the plastic sleeve into the holes,then fix the mounting plate with 4 25 screws. Measure the
position the wall hole with a measuring tape.
2.Drill a Hole through the Wall and Install the Piping Protective Sleeve
Drill a hole
60mm through the wall with the outer side slightly downward,then install the
piping sleeve,then seal it with gypsum powder.
3.Piping Layout for Indoor Unit
Lay out the connection pipe,drain pipe, and the connection wires according to the installation
position of the indoor and outdoor units. During the layout, the drain pipe shall be placed
underneath,and the connection wires shall be placed on the top; the drain pipe(especially indoor
or inside the unit)shall be wound up with the insulating material.
Right Connection
Left Connection
Low Connect on
i
Tape
Installation of the Connection Pipe Clips(Left or Left-Back Connection):
Insert the pipe clip into the fixing position of the pipe with the upper part inserted first.
Press the bottom of the clip until a sound Ka Ta
Pipe Clamp
Hanging Wire
Drop Wire Here
Mounting Plate
3
Wire
Holes for Fixing
Dropping Weight
A145mm
Find out the Level Position
A=185mm
60mm
Inter side
Outer side
Wall hole
Thickness of wall
60mm
(Section plan of wall hole)
Pipe
Insulating Material
Pipe Clamp
Drain Pipe
Electrical Connection
between Indoor and
Outdoor Units
is heard.
27