Haier AD422BMBAA Installation And Operation Manual page 24

Network air conditioner
Table of Contents

Advertisement

Installation procedure
5.
Drain hose
The drain hose should always have a slant degree (1/50~1/100) to avoid
(a)
the protruding part or causing water flow bend.
Good pipe system
Suspending screw bolt
1.5m*2m
Insulation
1/100 or more slant degree
(b) When connecting the drain hose with equipment, be sure not to use too
much force to the pipe on one side of the equipment.At the same time,
the fixation of pipe should be close to equipment as possible as it can.
(c) For the drain hose, it can be the local bought stiff PVC pipe for normal
purpose. When connecting, insert the end of PVC pipe into the drain
hole, then use drain hose and wire fastener to fix them tight. The bond
can not be used to connect drain hole and drain hose.
Drain hole
Drain hole
Main unit
Drain hose
Wire fastener (accessory)
Seal cushion (used for partition) (accessory)
22
Drain hose
Seal cushion (used for partition) (accessory)
Connector (local bought)
Bonded
Seal cushion (used for partition) (accessory)
Install indoor unit
*
Improper pipe system
Avoid protruding part
Do not have bend
Air outlet
**PVC*******
Do not put pipe under water