Haier AD242AHBEA Operation And Instruction Manual page 19

Duct type
Hide thumbs Also See for AD242AHBEA:
Table of Contents

Advertisement

Installation Manual For Indoor Unit
8. The attentive matters in installation of air suction and discharging duct
Recommend to use anti-frost and sound-absorbing
duct. (locally bought)
The duct installation work should be finished
before the fitment of ceiling.
The duct must be heat insulated.
The specific air-discharging outlet should be installed at
the place where the airflow can be reasonably distributed.
The surface should leave a checking meatus for checking
and maintenance.
9. The examples of improper installation
Do not use air in duct and take the ceiling inner side instead. The result is because of the irregular
outer air mass, strong wind and sunshine, the humidity is increased.
There may be water drop on the outside of duct. For cement and other new constructions, even if
not taking ceiling inner side as duct, the humidity will also be so high. At this time, use glass fiber
to perform heat preservation to the whole. (use iron net to bind the glass fiber)
Affected by the capacity of air discharging fan, the strong wind in the outer duct and wind direction,
when unit air sending volume exceeds the limit, the discharged water of heat exchanger will overflow,
leading to water leakage.
Air discharging fan
Improper example
18
Special air discharging outlet
Use screw bolt to fix
Air
Air
Duct

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad28nahbeaAd36nahbeaAd42nahbeaAd52nahbea

Table of Contents