SAFETY PRECAUTIONS

The machine is adaptive in following situation
1. Applicable ambient temperature range:
Cooling
Heating
2. If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
5. Use copper wire only. The connecting cable should be H05RN-F 4G 0.75mm
The power cable should be H07RN-F 3G 2.5mm
European allthentication certificate.
6. The power supply connects from the outdoor side.
7. The breaker of the air conditioner should be all-pole switch; and the distance
between its two contacts should be no less 3mm.
8. The indoor unit installation height is at least 2.5m.
Note:
Part of the power supply of the air conditioner are not prepared because of the
requirement of the dealer, the power supply should be provided for oneself.
DB C
Indoor
WB C
DB C
outdoor
WB C
Indoor
DB C
WB C
DB C
outdoor
WB C
5
Rated Maximum Minimum
27
32
19
23
35
43
24
26
20
27
14.5
--
7
24
6
18
2
. All the cables shall have got the
18
14
-5
--
15
--
-7
--
2
.