Sleep Operation - Haier 10530627 Operation Manual

Haier split type room air conditioner operation manual
Table of Contents

Advertisement

Available languages

Available languages

Operation

Sleep Operation

Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status,
then press SLEEP button before which the
clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
1
C
higher than temp.setting.After another 1 hours,
O
temp.rises by 1
C
futher.The unit will run for further
O
6 hours then stops Temp. is higher than temp.
setting so that room temperature won't be too low
for your sleep.
SLEEP operation starts
1 hr
Rises 1
1 hr
Temp.setting
In COOL, DRY mode
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will
become 2
C
lower than temp.setting.After
O
another 1 hours,temp decrease by 2
futher.After more another 3hours,temp.rises
by 1
O
futher.The unit will run for further 3
C
hours then stops.Temp.is lower than temp.
setting so that room temperature won't be
too high for your sleep.
Temp.setting
1 hr
Decreases 2
1 hr
Decreases 2
3 hrs
SLEEP
operation starts
In HEAT mode
4
SLEEP operation stops
Approx.6hrs
O
Rises 1
C
O
C
Unit stop
C
O
Unit stop
C
O
O
C
3 hrs
Rises 1
O
C
SLEEP
operation stops
In AUTO mode
3.
The unit operaters in corresponding sleep mode
adapted to the automatically selected operation
mode.
4. In FAN mode
It has no SLEEP function.
When quiet sleeping function is set to 8 hours ,
5.
the quiet sleeping time can not be adjusted.
When TIMER function is set , the quiet sleeping
function can't be set up. After the sleeping function
is set up, if user resets TIMER function, the sleeping
function will be cancelled; the machine will be in the
state of timing-on, if the two modes are set up at the
same time, either of their operation time is ended
first, the unit will stop automatically, and the other
mode will be cancelled.
Power Failure Resume Function
1. If the unit is started for the first time, the compressor
will not start running unless 3 minutes have elapsed.
When the power resumes after power failure, the unit will
run automatically, and 3 minutes later the compressor
starts running.
2. Note to the power failure resume:
press the sleep button ten times in five seconds and enter
this function after hearing four sounds. And press the sleep
button ten times within five seconds and leave this function
after hearing two sounds.
POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function.
In COOL mode, fan speed automatically takes high speed of
AUTO fan mode. In HEAT mode, fan speed automatically takes
medium speed of AUTO fan mode.
(2)
SOFT Operation
You can use this function when silence is needed for rest or reading.
In SOFT operation mode, fan speed
of AUTO fan mode.
Note
During POWER operation, in rapid HEAT or COOL mode the room
will show uniform temperature distribution. Long period
SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again, POWER or SOFT disappears.
automatically takes low speed

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hsu-24hek03/r2

Table of Contents