Emergency Operation; Test Operation - Haier 10518526 Operation Manual

Haier split type room air conditioner operation manual
Table of Contents

Advertisement

Operation
Emergency operation and test operation

Emergency Operation:

Carry out this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed, a" Pi "sound starts once, which
means the start of this operation.
In this operation, it is not possible to change the
settings of temperature and air flow speed, it is
also impossible to do an operation by the timer.
Follow the requirements below.
Room
temperature
o
More than 23
C
o
Less than 23
C
If an air conditioner is a model for both cooling and heating.
Cooling when the room temperature at the start of operation is above 23
Heating when the room temperature at the start of operation is below 23

Test operation:

Use this switch in the test operation when the room
temperature is less 16
operation.
Continue to press the test operation switch for more
than 5 seconds. After you hear the "Pi" sound twice,
release your finger from the switch, the cooling
operation starts with the air flow speed setting "Hi".
Removal of the restriction of emergency or test operation:
Press once more the emergency operation switch, or manipulate through the remote
controller, a "Pi" sound causes the restriction of emergency or test operation to be
removed.
When the remote controller is manipulated for the removal, then the selected operation
by the remote controller.
Timer
Designated
mode
temperature
o
26
C
CONTINUOUS
o
23
C
CONTINUOUS
o
C, do not use it in the normal
Air flow
Operation
speed
mode
AUTO
COOL
AUTO
HEAT
12
Pi
o
C.
o
C
Pi Pi

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents