Automatic Callback

FEATURE
DESCRIPTION
SYSTEM
AVAILABILITY
OPERATING
PROCEDURES
SERVICE
CONDITIONS
Features and Specifications Manual
After receiving a call waiting tone from a busy station, a user can set an
Automatic Callback. When both stations are idle, the system signals the
Automatic Callback originator first and, after answered, signals the
other station.
Terminal Type
All terminals.
Required Components
None.
To use this feature after calling a busy station and receiving a call
waiting tone:
1.
Dial Automatic Callback Access Code 0 (set as default).
2.
Hang up.
3.
The originating station rings when both stations become idle.
4.
Lift the handset or press
5.
Receive tone burst or ringback tone; talk when the called station user
answers.
Data Assignment
The Access Code can be changed to one of the following:
Restrictions
Only one Automatic Callback at a time may be set at a station.
Automatic Callback cannot be set to a station that is in Do Not
Disturb mode.
Call Pickup Group feature does not pickup Automatic Callback ringing
on the originator station.
Automatic Callback setting is automatically cancelled unless both
stations become idle within 30 minutes (set as default).