Uniform Numbering
Network
FEATURE
DESCRIPTION
SYSTEM
AVAILABILITY
OPERATING
PROCEDURES
Features and Specifications Manual
This feature allows multiple or compatible systems to be connected in a
network via Tie lines. Station users can access any station by dialling a
system number and a station number (open numbering) or by dialling the
station number only (closed numbering). If the calling and called systems
are not directly connected by a single Tie line, several Tie lines may be
accessed to route the call to the final destination. Each network system
automatically extends the call to the next system in line until the final
destination is reached.
Terminal Type
All terminals.
Required Components
TLI(2)-U( ) to provide Tie Line trunks.
To originate a call using the open numbering plan:
1.
Lift the handset, and receive internal dial tone.
2.
Dial the Tie Line Access Code.
3.
Dial the distant system number.
4.
Dial the station number.
To originate a call using the closed numbering plan:
1.
Lift the handset, and receive internal dial tone.
2.
Dial the station number of the remote party.
To answer a call:
1.
Go off-hook at the ringing station.
2.
Talk with calling party.
U-2