Shortcut
Class of Service (Station) Feature Selection 2
+BTS
Station to Class of Service Feature Assignment
+BTT
Trunk Queuing Timeout Selection
+BT
Features and Specifications Manual
If the queued outside line is not seized within the time specified in
System Programming, the queuing is released (default: 10 seconds.)
If a station that has set Trunk Queuing sets another queue, the original
Trunk Queue is cancelled.
If a station with a CO/PBX queue set is busy on a different call when
the queued line becomes available, the outside line can be seized by
another station. Trunk Queuing is still set until both the trunk and
station are idle at the same time.
The station user that set an outside line queue can cancel it by dialling
an Access Code.
When the station user places an outside call using LCR, Trunk
Queuing cannot be set.
When Call Appearance keys are in use, Trunk Queuing cannot be set
on the busy Call Appearance key.