Xen IPK
Features and Specifications Manual
Use Memory Block 1-9-03 (ID Code Restriction Class Assignment -
Day Mode) and 1-9-04 (ID Code Restriction Class Assignment - Night
Mode) to specify the day and night mode code restrictions classes for
each ID number.
Use Memory Block 4-26 (DISA ID Number Station Assignment) to
assign the Direct Inward System Access (DISA) ID Buffer Number
corresponding to the station port number.
Use Memory Block 4-27 (ID Outgoing Restriction Selection) to specify
which ID Numbers can be entered to override code restriction
per station.
General
A maximum of 120 ID Numbers can be assigned.
The ID Password can be from 1 to 10 digits (default: 0000000000).
Once a user has entered 10 digits while setting a new ID Password,
the process automatically ends and the new password is accepted. If
the user goes on-hook before entering the full 10 digits, the shorter
password is accepted as the new password.
Override passwords can have different access depending upon the
system's mode, day or night.
Error indication is produced if a user attempts to set, verify or reset a
password on a station is not assigned with this feature.
Code Restriction Override is allowed when the ID Number and ID
Password match.
Whether entry of an ID Password is required or not is specified in
system programming.
A desired ID Number must be assigned to a specific ID management
number.
Origination of a call from a station with restriction set in terms of an ID
management number (Memory Block 4-27) is denied if the call is
placed in terms of the corresponding ID Number.
The procedures to originate an Override call and set an ID Password
can be performed at all the stations.
The procedures to reset and confirm an ID Password can be
performed at Attendant stations only.
The number of digits of the ID Number is determined by the setting of
Memory Block 1-2-03 (2-, 3-, or 4-Digit Station Number Selection).
The Code Restriction Password Override feature and the Forced
Account Code feature cannot be used concurrently.
The trunk selection in Memory Block 1-1-19 (Automatic Outgoing Line
Selection) are only used when an Override call is originated.