[50MXE20]
(2) When the Plasma Display is in a confined space
Operating this display in confined spaces is not recommended.
• If the display is to be used in confined spaces, observe the following conditions shown in the drawing below:
A ≥ 50
• If heat remains in the enclosed space, the temperature may rise causing a malfunction or fire. As a precaution, the
inner wall should have sufficient heat resistance or fire resistance.
• Leave a space at least 10 mm wide when installing glass etc. on the front of the Plasma Display.
✩ Usage temperature conditions
• Ambient temperature: 0 °C to 35 °C (Outside air temperature)
• Space enclosed by the back surface of the Plasma Display: 0 °C to 35 °C (Use a fan etc. to discharge air to
maintain this temperature range.)
*1
For this installation, set the 'FAN CONTROL' to 'MAX' as shown in "5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting" (pg. 211).
: Thermometer (temperature measurement point)
Note
When installing the Plasma Display facing upwards, do not place anything on top of it nor apply any load on it from
above.
Special installation (Installed facing upward)
(*1)
Outside air temperature
measuring point
50 mm
Enclosed space air temperature
measuring point
Outside air
temperature
measuring point
A
A ≥ 50
Enclosed space air
temperature measuring
point
10 mm
53