Removing An Element Control (Infinite Switch) & A Surface Indicator Light - Whirlpool 4322525 Manual

Self-cleaning slide-in electric ranges
Table of Contents

Advertisement

REMOVING AN ELEMENT CONTROL (INFINITE SWITCH)
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in death or
electrical shock.
CAUTION: When you work on the range, be
careful when handling the sheet metal parts.
Sharp edges may be present, and you can cut
yourself if you are not careful.
1.
Turn off the electrical power to the range.
2.
Remove the control panel (see page 4-2
for the removal procedure). NOTE: You
do not have to remove the electronic oven
control from the panel.
Refer to Figure 4-4 for the following steps.
3.
To remove an element control:
a) Remove the two mounting screws from
the element control.
b) Rotate the control panel back on top
of the maintop so you can access the
element control wiring.
c) Disconnect the wires from the termi-
nals on the element control and recon-
nect them to the identically-marked ter-
minals of the new control (see the in-
set).
& A SURFACE INDICATOR LIGHT
4.
To remove a surface indicator light:
a) Hold the lens in place with one hand
and unclip the indicator light from the
lens (see Figure 4-3).
PRESS UP
TO ENGAGE
CLIPS WITH
LENS SHOULDER
b) Disconnect the one indicator light lead
from the element control terminal, and
cut the other lead near the indicator
light body.
c) Connect the lug on the lead of the new
indicator light to the element control
terminal.
d) Remove 3/8" of insulation from the cut
wire ends and splice them together us-
ing a twist-on nut.
4-4
CONTROL
PANEL
SLIDE LIGHT
HOLDER CLIPS
OVER/OFF SHOULDER
Figure 4-3