7.
Mount the green ground lead from the
power cord to the grounding link with the
grounding link screw you just removed
(see Figure 2-9). This lead must be at-
tached first and must not contact any
of the other terminals.
Silver
Terminal
Green
(ground)
Lead
Figure 2-9
Connecting The Leads
White
(neutral)
Lead
Strain Relief
2-5
8.
Using the brass terminal nuts you re-
moved in step 3, connect the power supply
cord lead ends to the terminal screws as
follows (see Figure 2-9):
a) White (neutral) lead to the center (sil-
ver) terminal screw. This lead must be
connected to the center terminal.
b) Remaining two leads to the outer
screw terminals.
9.
Make sure that the conduit strain relief is
tight, then mount the terminal block cover
to the range with the hardware you re-
moved in step 3.