BEA 10DPHUB User Manual
BEA 10DPHUB User Manual

BEA 10DPHUB User Manual

Door position system

Advertisement

Quick Links

1 Description
The DP-Hub (10DPHUB) is a programmable lockout module used for
any automatic swing door in conjunction with the EDPS, Enhanced
Door Position Sensor, (10DPS) to provide accurate door position.
The accurate door position provides:
- Automatic inhibiting of the safety side Door Mounted Sensor(s)
without the need for an external mechanical limit switch.
- A manual push of the door or stack pressure will no longer effect the
overhead presence.
The hub also provides sensor plug-in connectors, and easy 2-button
digital programming with a user-friendly display. The DP-Hub product
line is identifi ed by a solid black housing.
2 Specifi cations
DESCRIPTION
SPECIFICATION
Supply voltage
12 to 24 VAC/VDC: +/- 10%
Power consumption
80mA max. (hub only)
Temperature range
-20°F to +150°F
Dimensions
4.5" W x 2.5" D x 1.25" H
Housing material
ABS – Solid Black
Relay Specifi cations
2A, 30 VDC
.3A, 110 VDC
.5A, 125 VAC
3 Precautions
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffi c around the door area.
Always stop pedestrian traffi c through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board
ensure you dissipate your body's ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by
BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
4 Pre-Installation Check
1.
When preparing to wire multiple devices together for a 'system' confi guration, it is best to ensure the correct operation of each device
independently before starting thereby reducing troubleshooting time later in the event of a discrepancy. Thus make sure the door is running
correctly and adjusted properly before installing Door Position System.
2.
Prior to installing equipment on an existing installation or when installing equipment on a new installation, utilizing new electrical supply
circuits, always ensure the correct line voltage exists and is stable. Remember to disconnect the power after checking the line voltage and
before performing any wiring to the system.
75.5652.01 20100830
Door Position System
PROGRAMMABLE LOCKOUT MODULE WITH DOOR POSITION
COMPONENT INPUTS
(2) Eagle Motion Sensors
(1) BodyGuard Sensor */**
(2) Pair of Door Mounted Sensors w/ EDPS &
Home switch
(2) Manual Door Mounted Stall Inhibit Terminals
(1) Auxiliary: Push Plates, RF, etc.
(1) SBK 30 Photo Beam pair
(1) ON/OFF/HOLD Switch
* For dual egress, use Y-harness for second
BodyGuard.
** For independent dual egress, two hubs are
required.
USER'S GUIDE
COMPONENT OUTPUTS
(2) Door Control
Page 1 of 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 10DPHUB and is the answer not in the manual?

Questions and answers

Summary of Contents for BEA 10DPHUB

  • Page 1 USER’S GUIDE PROGRAMMABLE LOCKOUT MODULE WITH DOOR POSITION 1 Description The DP-Hub (10DPHUB) is a programmable lockout module used for any automatic swing door in conjunction with the EDPS, Enhanced Door Position Sensor, (10DPS) to provide accurate door position. The accurate door position provides: - Automatic inhibiting of the safety side Door Mounted Sensor(s) without the need for an external mechanical limit switch.
  • Page 2: Installation

    NOTE: When changing the state of the ON/OFF/HOLD switch, the door will not open or close if the Bodyguard is in detection. NOTE: If the door control also has an ON/OFF/HOLD switch, make sure to jump it to the ON position and use the BEA ON/OFF/HOLD Switch.
  • Page 3 1. For complete installation instructions refer to BodyGuard User’s Guide (75.5134). NOTE: BEA recommends the use of the Bodymount during all Bodyguard installations. NOTE: On a single door installation the Bodyguard should be angled to 10 degrees (5 degrees default).
  • Page 4 5 Installation (continued) Install Door Mounted Sensor(s) Door Mounted 1 (SuperScan shown in example) EMPTY Door Mounted 2 INHIB GND INHIB + N.O. Door Mounted 1 Cable GREEN N.C. Route to ‘DM 1’ WHITE BLACK Door Mounted 2 Cable Route to ‘DM2’ Make sure to set the SuperScan’s JP2 to the default (as shown) to make the SuperScan have a...
  • Page 5 5 Installation (continued) Install Home Switch Magnet installed in end Surface Mount Adapter Magnetic reed cap exploded and installed exploded and Installed switch wired into EDPS End cap with Home Switch Collar exploded 1. Snap the Home Switch Collar with the magnetic reed switch into the correct end cap and install the end cap on the Door Mounted Sensor extrusion.
  • Page 6 5 Installation (continued) Install Eagle(s) (optional) Eagle 1 Cable Eagle 1 Route to 1 POWER ‘EG 1’ Eagle 2 BLACK 2 POWER WHITE 3 COM GREEN 4 N.O. Eagle 2 Cable Route to 5 N.C. ‘EG 2’ 1. For complete installation instructions refer to Eagle User’s Guide (75.0058). 2.
  • Page 7 2. Route wiring harness (20.5095) from the Transformer to DP-Hub and plug into DP-Hub at location marked ‘POWER’. NOTE: Alwasy use the BEA supplied transformer and never power the DP-Hub from the door control. 75.5652.01 20100830 Page 7 of 16...
  • Page 8 5 Installation (continued) Confi gure BodyGuard III BODYGUARD III 1. Unlock BodyGuard Sensor 2. Set Output Confi guration Normally Closed OUTPUT CONFIGURATION 3. Lock Sensor by pressing Lock twice - Normally OPEN Relay (default) - Normally Closed Relay CAUTION: When using the remote control to adjust the Bodyguard, make sure you do not accidentally change the settings on any other sensors.
  • Page 9 5 Installation (continued) Perform Door Position System Learn LEARN MODE After all of the programming has been performed to the DP-Hub, make sure that there is NO pedestrian traffi c for approximately two minutes and: 1. Make sure orange Home LED is on. Make sure the ON/OFF/HOLD Switch is set to ON. Then set the DP-Hub into Learn Mode by fi rst pressing the ‘FUNCT’...
  • Page 10 6 Programming the DP-Hub Very little programming is required on the DP-Hub as the default parameters should suffi ce for most systems. The DP-Hub can display two sets of information to the user. These sets are programming parameters and operating parameters. Programming Parameters (Adjustable) The fi...
  • Page 11 6 Programming the DP-Hub (continued) Operating Parameters (Troubleshooting) 1. The second set of parameters provides a set of real-time operating parameters for troubleshooting. These displays are available only to view, with no user interaction possible. They merely provide the operating status of the system. The chart below shows these displays. Once one of these operating parameters has been selected, the display will remain active on that parameter and NOT time out, thus NOT saving any programmed parameters until one of the programming parameters has been selected.
  • Page 12: Troubleshooting

    LEDs on the DP-Hub. The description of the LEDs is shown below. Once the problem is determined the corrective actions can be taken as specifi ed by the second table. Finally if you cannot solve the problem on your own, you can contact BEA Technical Support whose contact information is provided in Section 9.
  • Page 13 A safety check that includes at a minimum the items listed on the safety information label must be performed during each service call. If you are not an AAADM certifi ed inspector BEA strongly recommends to have an AAADM certifi ed inspector perform an AAADM inspection and placing a valid inspection sticker below the safety information label prior to placing the equipment into operation.
  • Page 14: Appendix A - Wiring Diagram

    Appendix A - Wiring Diagram BLACK WHITE GREEN BLACK WHITE GREEN BLACK WHITE GREEN BLACK BLACK WHITE WHITE GREEN GREEN BLACK WHITE GREEN Page 14 of 16 75.5652.01 20100830...
  • Page 15: Appendix B - Door Controls

    Appendix B - Door Controls Green/ Yellow/ White/ Green/ Yellow/ White/ DP-Hub Wire Color Green Yellow White Black Black Black SAFE SAFE SAFE STALL STALL STALL Door Control Besam 300 Besam MP/CUP Besam SM900/CU2 Door O Matic Yellow Grey Blue Grey Purple Grey...
  • Page 16 Appendix C - Home Switch (continued) Alternative Solutions Magnetic bullet switch in the nose of the Mechanical limit switch on door operator If you cannot use the typical installation, perhaps due to vertical rods or the customer does not like the look of the Surface Mount Adapter, there are several alternatives.

Table of Contents