1 Description
The DP-Hub (10DPHUB) is a programmable lockout module used for
any automatic swing door in conjunction with the EDPS, Enhanced
Door Position Sensor, (10DPS) to provide accurate door position.
The accurate door position provides:
- Automatic inhibiting of the safety side Door Mounted Sensor(s)
without the need for an external mechanical limit switch.
- A manual push of the door or stack pressure will no longer effect the
overhead presence.
The hub also provides sensor plug-in connectors, and easy 2-button
digital programming with a user-friendly display. The DP-Hub product
line is identifi ed by a solid black housing.
2 Specifi cations
DESCRIPTION
SPECIFICATION
Supply voltage
12 to 24 VAC/VDC: +/- 10%
Power consumption
80mA max. (hub only)
Temperature range
-20°F to +150°F
Dimensions
4.5" W x 2.5" D x 1.25" H
Housing material
ABS – Solid Black
Relay Specifi cations
2A, 30 VDC
.3A, 110 VDC
.5A, 125 VAC
3 Precautions
Shut off all power going to header before attempting any wiring procedures.
Maintain a clean & safe environment when working in public areas.
Constantly be aware of pedestrian traffi c around the door area.
Always stop pedestrian traffi c through the doorway when performing tests that may result in unexpected reactions by the door.
ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board
ensure you dissipate your body's ESD charge.
Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause
damage to equipment.
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by
BEA, Inc. Unauthorized disassembly or repair:
1. May jeopardize personal safety and may expose one to the risk of electrical shock.
2. May adversely affect the safe and reliable performance of the product resulting in a voided warranty.
4 Pre-Installation Check
1.
When preparing to wire multiple devices together for a 'system' confi guration, it is best to ensure the correct operation of each device
independently before starting thereby reducing troubleshooting time later in the event of a discrepancy. Thus make sure the door is running
correctly and adjusted properly before installing Door Position System.
2.
Prior to installing equipment on an existing installation or when installing equipment on a new installation, utilizing new electrical supply
circuits, always ensure the correct line voltage exists and is stable. Remember to disconnect the power after checking the line voltage and
before performing any wiring to the system.
75.5652.01 20100830
Door Position System
PROGRAMMABLE LOCKOUT MODULE WITH DOOR POSITION
COMPONENT INPUTS
(2) Eagle Motion Sensors
(1) BodyGuard Sensor */**
(2) Pair of Door Mounted Sensors w/ EDPS &
Home switch
(2) Manual Door Mounted Stall Inhibit Terminals
(1) Auxiliary: Push Plates, RF, etc.
(1) SBK 30 Photo Beam pair
(1) ON/OFF/HOLD Switch
* For dual egress, use Y-harness for second
BodyGuard.
** For independent dual egress, two hubs are
required.
USER'S GUIDE
COMPONENT OUTPUTS
(2) Door Control
Page 1 of 16