31833137.fm Page 13 Friday, July 9, 2004 2:37 PM
HOO B00 - B01
HOO B20 - B24
INSTALLATION - ASSEMBLY INSTRUCTIONS
Preliminary information for installing the hood:
Do not connect the hood to the power supply during the installation phase.
Warning! The 2 fixing brackets are packed with polystyrene protection. There is a right R and a left L bracket (see bracket
punching).
1. Fix brackets D (Fig. 1) to the sides of the wall unit using two screws per bracket (right bracket R on the right, left bracket
L on the left); the brackets must be parallel with the lower edge of the unit.
Position the support bracket so that it is against the back of the wall unit, making sure that the rear edge of the bracket
matches the back of the hood.
Drill an opening at the top of the wall unit for the exhaust pipe and the power supply cable.
2. Fit the hood inside the wall unit, being careful to position the hood bracket E above the wall unit bracket D (Fig. 1-2).
Insert the power supply cable through the opening made for the purpose.
3. Secure the hood with two screws in front (Fig. 2 - one each side).
4. Carry out the electrical connection to the mains power supply, only turn on the power supply with assembly completed.
5. If necessary, adjust the alignment by loosening the screws P of the brackets E mounted on the hood (Fig. 3) until the
hood and the lower edge of the wall unit line up perfectly, then tighten the screws again.
6. Adjust the deflector slideout stroke according to the depth of the wall unit by adjusting the two retainers F (Fig. 5). In
this way the front will be perfectly aligned with the wall unit.
a.
Loosen the screws of the retainers F;
b.
adjust by moving the retainers backwards or forwards;
c.
tighten the screws of the retainers.
7. Fix an outlet duct to the collar C supplied. The outlet duct diameter should be the same as that of the collar (Fig. 4). The
exhaust pipe must be long enough to vent externally (extractor version) or must reach the top of the wall unit (filter
version).
8. Fix the collar C (snap-close) to the top section of the hood discharge.
To facilitate installation, the collar has a mark G that must match the specific guide H on the exhaust duct.
9. Complete the installation of the exhaust duct.
Refit the grease filter/s, connect the hood to the power supply and check for correct hood operation.