Lamp Replacement Counter - Panasonic PLC-XU75A Owner's Manual

Multimendia projector
Table of Contents

Advertisement

Maintenance and Cleaning

Lamp Replacement Counter

Be sure to reset the Lamp replacement counter after the lamp is replaced. When the Lamp
replacement counter is reset, the LAMP REPLACE indicator stops lighting.
1
Turn the projector on, press the MENU button to
display the On-Screen Menu. Press the Point
buttons to move the red framed pointer to the
8
Setting Menu icon.
2
Press the Point
framed pointer to the Lamp counter function and
then press the SELECT button. The first dialog box
appears and shows the total accumulated time of
the lamp usage and the reset option. If you select
"Reset", a "Lamp replacement counter Reset?"
message appears. Select [Yes] to continue.
3
Another confirmation dialog box appears, select
[Yes] to reset the Lamp replacement counter.
Note:
Do not reset the Lamp replacement counter
without implementation of lamp replacement. Be
sure to reset the Lamp replacement counter only
after replacing the lamp.
This projector uses a high-pressure lamp which must be handled carefully and properly.
Improper handling may result in accidents, injury, or create a fire hazard.
● Lamp life may differ from lamp to lamp and according to the environment of use. There is no guarantee
of the same life for each lamp. Some lamps may fail or terminate their life in a shorter period of time than
other similar lamps.
● If the projector indicates that the lamp should be replaced, i.e., if the LAMP REPLACE indicator lights up,
replace the lamp with a new one IMMEDIATELY after the projector has cooled down. (Follow carefully the
instructions in the Lamp Replacement section of this manual.) Continuous use of the lamp with the LAMP
REPLACE indicator lighted may increase the risk of lamp explosion.
● A Lamp may explode as a result of vibration, shock or degradation as a result of hours of use as its lifetime
draws to an end. Risk of explosion may differ according to the environment or conditions in which the
projector and lamp are being used.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector's AC plug from the AC outlet immediately. Contact an authorized
service station for a checkup of the unit and replacement of the lamp. Additionally, check carefully to ensure
that there are no broken shards or pieces of glass around the projector or coming out from the cooling air
circulation holes. Any broken shards found should be cleaned up carefully. No one should check the inside of
the projector except those who are authorized trained technicians and who are familiar with projector service.
Inappropriate attempts to service the unit by anyone, especially those who are not appropriately trained to do
so, may result in an accident or injury caused by pieces of broken glass.
56
buttons to move the red
ed
LAMP HANDLING PRECAUTIONS
7
Select [Yes] again
to reset the lamp
counter.
To reset the lamp counter,
move the pointer to
Reset and then press the
SELECT button. "Lamp
replacement counter
Reset?" dialog box is
displayed.
Select [Yes],
then another
confirmation
box appears.

Advertisement

Table of Contents
loading

Table of Contents