Termination Settings

To prevent the attenuation of communication signals between the camera and controller, the
items at the end of line must be set up with the termination settings.
Camera Input Position
Termination of Longest Path
On the Path
* This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.
Notes
• To use a third party controller with this product, please contact our After-Sales Service
or Technology Department.
• Controls Using Different Protocols
Entering Camera OSD
Exiting Camera OSD
ENTER
ESC
• For more information about the protocols, refer to our official website.
Control with the SSC-5000 Controller
Protocol
Samsung-T
Samsung-E
• Note that LCD monitor does not switch to OSD mode and the Joystick will not provide
Enter operation, when using the OSD menu with Samsung-E protocol.

Camera ID DIP Switch Settings (SW1)

To set up camera IDs, refer to the "Camera ID Chart" next.
ON
SW2- #8
ON
OFF
AD Protocol
VICON Protocol
3+Auxilary ON
3+Auxilary OFF
IRIS CLOSE
IRIS OPEN
IRIS CLOSE
IRIS CLOSE
Enter
Focus Far
Iris Open/Focus Far
SW1
21
SPEED DOME CAMERA
GE Protocol
IRIS OPEN
IRIS OPEN
IRIS CLOSE
IRIS OPEN
IRIS OPEN
IRIS CLOSE
Esc
Focus Near
Iris Open/Focus Near