C. Check Firebox Molded Brick Panel
Frequency: After each ash removal
By: Homeowner
WARNING! Risk of Fire! Inspect fi replace molded brick
panel. Crumbling, deteriorated molded brick panel can al-
low overheating of surrounding materials.
Expansion and contraction will cause minor cracking of the
molded brick panel. This is normal. The panel will require
periodic replacement depending on use.
The panels should be replaced if
Cracks exceed ¼ inch (6 mm) in width,
Metal is exposed behind a panel,
Large pieces of panel fall out.
NOTICE: Do not substitute for HHT mortar. Other materials
may stain the molded brick panels.
D. Inspect Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
Warping or sagging 1-1/2 in. (38 mm) or more
Broken welds
Burn-through of grate bars
For safe operation, replace only with the approved grate
from Hearth & Homes Technologies Inc.
E. Glass Cleaning
Frequency: As desired
By: Homeowner
CAUTION! Handle glass assembly with care. Glass is
breakable.
Avoid striking, scratching or slamming glass
Avoid abrasive cleaners
Do not clean glass while it is hot
Clean glass with a non-abrasive commercially available
cleaner or ashes:
Light deposits
-
Use household glass cleaner
Heavy deposits
-
Use wood ash on damp cloth or,
-
Use commercial fi replace glass cleaner (consult with
your dealer)