Programming (Cont.)

Master/Slave

Color Settings

Dimmer Curves

Control Panel Lock

March 3, 2010
The Master/Slave mode allows a group of COLORado™ Batten 72 Tour fixtures (the
slaves) to execute simultaneously the same program, whether auto or custom, that
another COLORado™ Batten 72 Tour fixture (the master) is executing, and without a
DMX controller.
1) Set the Master Unit:
a) Set the running mode to DMX as explained in "DMX Control Without ID
Addressing"
b) Select an Auto program as explained in "Auto Programs".
2) Set the slave units:
a) Press <MENU> repeatedly until RUN shows, and press <ENTER> to accept.
b) Use <UP> or <DOWN> to select SLAVE, and press <ENTER> to accept.
c) Press <MENU> to return to the main level.
a) The fixture that runs an auto program automatically becomes the Master.
b) Do not connect a DMX controller to the master or slave fixtures.
The COLOR setting determines how the COLORado™ Batten 72 Tour generates the
white color based on various RGB settings.
1) Press <MENU> repeatedly until SETTINGS shows, and press <ENTER> to accept.
2) Use <UP> or <DOWN> to select COLOR, and press <ENTER> to accept.
3) Use <UP> or <DOWN> to select OFF, RGB TO W or UC.
4) Press <ENTER> to accept.
4) Press <MENU> twice to exit to the main level.
OFF = When RGB are all set to "255", output is maximum.
RGB TO W = When RGB are all set to "255", output is the defined by the
configured White color (see Whites Setting).
UC = RGB are all set to the produce the same universal color
This setting determines the output of the COLORado™ Batten 72 Tour based on the
position of the Red, Green, Blue, White and Dimmer faders.
1) Press <MENU> repeatedly until SETTINGS shows, and press <ENTER> to accept.
2) Use <UP> or <DOWN> to select DIMMER, and press <ENTER> to accept.
3) Use <UP> or <DOWN> to select a dimmer curve (OFF, DIM1, DIM2, DIM3 or DIM4).
4) Press <ENTER> to accept.
When Dim is set to "OFF", the output is proportional (linear) to the Dimmer and
RGBW channel values.
When Dim is set to "DIM1" through "DIM4", the output follows the Dimmer and
RGBW channel values based on the corresponding dimmer curve, being DIM1
the fastest and DIM4 the slowest.
This setting allows the user to activate or disable the control panel lock, which keeps
non-authorized personnel from changing the fixture's settings.
1) Press <MENU> repeatedly until KEYLOCK shows, and press <ENTER> to accept.
2) Use <UP> or <DOWN> to select ON or OFF, and press <ENTER> to accept.
When the control panel lock is active, the fixture will prompt the user to enter the
password after 30 seconds of control panel inactivity or after turning on the
fixture.
After being prompted to enter the password:
1) Press <UP>, <DOWN>, <UP>, <DOWN> and <ENTER>