Fujitsu M10-4/Fujitsu M10-4S/
SPARC M10-4/SPARC M10-4S
Service Manual
Manual Code: C120-E682-07EN
February 2014

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu SPARC M10-4

  • Page 1 Fujitsu M10-4/Fujitsu M10-4S/ SPARC M10-4/SPARC M10-4S Service Manual Manual Code: C120-E682-07EN February 2014...
  • Page 3 Contents                                                                              ...
  • Page 4                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 5                                                                                  ...
  • Page 6                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 7                                                                                  ...
  • Page 8                                                           Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014 viii...
  • Page 9                                                                                  ...
  • Page 10                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 11                                                                                  ...
  • Page 12                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 13                                                                                  ...
  • Page 14                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 15                                                                                  ...
  • Page 16                                                             Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 17                                                                                  ...
  • Page 18                                                           Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014 xviii...
  • Page 19                                               Contents...
  • Page 20   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 21 Preface ■ ■ ■ ■ ■ ■   Audience...
  • Page 22: Related Documentation

    Related Documentation ■ ■ Documentation Related to SPARC M10 Systems (*1) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014 xxii...
  • Page 23: Text Conventions

                                auditadm Command syntax in the text Notes on Safety Fujitsu M10/SPARC M10 Systems Important Legal and Safety Information ■ Fujitsu M10/SPARC M10 Systems Safety and Compliance Guide ■...
  • Page 24: Syntax Of The Command-Line Interface (Cli)

    Syntax of the Command-Line Interface (CLI) ■ ■ ■ Document Feedback ■ ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014 xxiv...
  • Page 25: Before Starting Maintenance Work

    Chapter 1 Before Starting Maintenance Work ■ ■ ■ ■ ■ ■ ■ Warning/Caution Indications Warning Caution...
  • Page 26: Warning Labels

    Warning Labels Caution Figure 1-1     Figure 1-2     Labels/Tags Note Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 27 ■ ■   ■ ■ ■   ■ ■ ■ Figure 1-3     Figure 1-4     Chapter 1 Before Starting Maintenance Work...
  • Page 28 ■ Figure 1-5     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 29: Safety Precautions

    Figure 1-6     Safety Precautions ■ ■ ■ Chapter 1 Before Starting Maintenance Work...
  • Page 30: Notes Regarding Static Electricity

    ■ ■ ■ ■ Safety precautions on the racks ■ ■ ■ ■ ■ Fujitsu M10/SPARC M10 Systems Installation Guide Notes Regarding Static Electricity Table 1-1     Item Precaution Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 31: Other Precautions

    How to use a wrist strap Caution - Figure 1-7     Other Precautions ■ ■ Chapter 1 Before Starting Maintenance Work...
  • Page 32: Emergency Power Off

    ■ ■ ■ ■ ■ ■ ■ ■ Emergency Power Off Caution Remove all the power cords from the power supply unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 33 Figure 1-8     Figure 1-9     Chapter 1 Before Starting Maintenance Work...
  • Page 34 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 35: Understanding The System Components

    Chapter 2 Understanding the System Components ■ ■ ■ ■ Identifying the Names and Locations of Components Components that can be accessed from the front...
  • Page 36 Figure 2-1     Location number Component Figure 2-2     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 37 Location number Component Components that can be accessed from the rear Figure 2-3     Location number Component Chapter 2 Understanding the System Components...
  • Page 38: Internal Components

    Figure 2-4     Location number Component Internal components Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 39 Figure 2-5     Location number Component Chapter 2 Understanding the System Components...
  • Page 40: Confirming The Functions Of The Operation Panel

    Figure 2-6     Location number Component Confirming the Functions of the Operation Panel Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 41: Chapter 2 Understanding The System Components

    Figure 2-7     Chapter 2 Understanding the System Components...
  • Page 42 Figure 2-8     Figure 2-9     Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 43: Display Function Of The Operation Panel

    Location number Component Table 2-1     LEDs/switches on If the SPARC M10-4S or the crossbar box is acting If the SPARC M10-4S or the crossbar box is acting operation panel as the master XSCF as an XSCF other than the master XSCF 2.2.1 Display function of the operation panel ■...
  • Page 44: Control Function Of The Operation Panel

    Figure 2-10     Location number Component 2.2.2 Control function of the operation panel ■ ■ ■ Figure 2-11     Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 45 Location number Component Table 2-2     Operation Description Table 2-3     Icon Name Description Chapter 2 Understanding the System Components...
  • Page 46 Table 2-4     Icon Operation Description started in Service mode (*): started in Locked mode (*): started in Service mode (*): Table 2-5     Function Mode switch Locked Service Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 47: Checking The Led Indications

    Table 2-5     Function Mode switch Locked Service Checking the LED Indications 2.3.1 Operation panel LEDs Table 2-6     Icon Name Color Description ● ● ● ● ● ● Chapter 2 Understanding the System Components...
  • Page 48: Leds On The Rear Panel (System Locator)

    Table 2-6     Icon Name Color Description ● ● ● Table 2-7     LED state Description POWER XSCF CHECK STANDBY 2.3.2 LEDs on the rear panel (System locator) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 49 Figure 2-12     Chapter 2 Understanding the System Components...
  • Page 50: Leds On Each Component

    Figure 2-13     Table 2-8     Icon Name Color Description ● ● ● 2.3.3 LEDs on each component   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 51 Table 2-9     Name Color Status Description Table 2-10     Name Color Status Description Table 2-11     Name Color Status Description Chapter 2 Understanding the System Components...
  • Page 52 Table 2-12     Name Color Status Description Table 2-13     Name Color Status Description Table 2-14     Name Color Status Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 53: Confirming The Types Of Cable

    Confirming the Types of Cable 2.4.1 Types of cable ■ ■ ■ ■ 2.4.2 Cable connection ports ■ ■ ■ ■ Chapter 2 Understanding the System Components...
  • Page 54 Figure 2-14     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 55 Figure 2-15     Location number Connection port Chapter 2 Understanding the System Components...
  • Page 56 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 57: Troubleshooting

    Chapter 3 Troubleshooting ■ ■ ■ ■ Suspected Failure Conditions ■ ■ ■ ■ Determining the Causes of Individual Failures...
  • Page 58: Identifying A Failure

    OS and XSCF consoles. Execute showlogs on XSCF to display failure information. Check /var/adm/messages on Oracle Solaris. Write down the displayed failure information. Contact our service engineer. Identifying a Failure Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 59: Checking Error Messages

    Checking the LED indications ■ ■ ■ 3.3.2 Checking error messages ■ Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide ■ Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide 3.3.3 Checking the status of a component showhardconf command Log in to the XSCF shell.
  • Page 60 Execute the showstatus command to check the status. XSCF>   showstatus         MBU   Status:Normal; *               MEM#0A   Status:Faulted; Table 3-1     Display Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 61 Table 3-1     Display Description 3.3.4 Checking the status of a PCI expansion unit ioxadm command Log in to the XSCF shell. Execute the ioxadm command to check the environmental conditions of the specified PCI expansion unit. XSCF>   ioxadm env -te PCIBOX#2008 Location  ...
  • Page 62         FRU:   PSU#1,PSU#2,   PSU#3,*         Msg:   ACFAIL   occurred   (ACS=3)(FEP   type   =   A1) Table 3-2     Operand Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 63 3.3.6 Checking the messages output by the predictive self-repairing tool ■ ■ ■ ■ Table 3-3     Output Displayed Description : : : : : : : : : : : : : : : : : : : :...
  • Page 64: Downloading Error Log Information

    Execute the setlocator command to blink the CHECK LED of the chassis requiring maintenance, and determine its location. XSCF>   setlocator -b 1 blink Downloading Error Log Information Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 65: Preparing Tools Required For Maintenance

    Chapter 4 Preparing for Maintenance ■ ■ ■ Preparing Tools Required for Maintenance Table 4-1 Item Confirming the System Configuration...
  • Page 66 XSCF> showhardconf ■ ■ ■ ■ ■ 4.2.2 Confirming the software and firmware configurations Confirming the software configuration Table 4-2     Command Description Displays logical domain configuration information. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 67 Log in to the control domain console of the physical partition where the component to be maintained is mounted. Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Execute the pkg(1) command to display Oracle Solaris correction information and version.
  • Page 68 Log in to the XSCF shell. Execute the version command to determine the firmware version information. XSCF>   version -c xcp Understanding Types of Maintenance Table 4-4     Configuration Description ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 69 Figure 4-1     Physical partition (active) Physical partition (active) BB#0 BB#3 XBBOX BB#1 BB#4 Physical partition (active) Physical partition (active) BB#2 BB#5 Figure 4-2     Physical partition (active) Physical partition (active) BB#0 BB#3 XBBOX BB#1 BB#4 Physical partition (active) Physical partition (active) BB#2 BB#5...
  • Page 70 BB#4 Physical partition (active) Physical partition (active) BB#2 BB#5 Figure 4-4     Physical partition (active) Physical partition (active) BB#0 BB#2 Cold BB#1 Physical partition (active) BB#3 XBBOX BB#4 ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 71 Figure 4-5     Physical partition (stopped) Physical partition (active) BB#0 BB#3 XBBOX BB#1 BB#4 Physical partition (active) Physical partition (active) BB#2 BB#5 Figure 4-6     Physical partition (stopped) Physical partition (active) BB#0 BB#3 XBBOX BB#1 BB#4 Physical partition (active) Physical partition (active) BB#2 BB#5...
  • Page 72 Physical partition (active) BB#2 BB#5 ■ Figure 4-8     Physical partition (stopped) Physical partition (stopped) BB#0 BB#3 XBBOX Cold BB#1 BB#4 Physical partition (stopped) Physical partition (stopped) BB#2 BB#5 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 73 Figure 4-9     Physical partition (stopped) Physical partition (stopped) BB#0 BB#3 XBBOX Cold BB#1 BB#4 Physical partition (stopped) Physical partition (stopped) BB#2 BB#5 Figure 4-10     Physical partition (stopped) Physical partition (stopped) BB#0 BB#2 Cold BB#1 Physical partition (stopped) BB#3 XBBOX BB#4...
  • Page 74 Table 4-5     Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Reference Table 4-6     Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Reference Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 75 Table 4-6     Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Reference Table 4-7     Active/hot Active/cold Inactive/hot Inactive/cold System stopped Reference Table 4-8     Active/hot Active/cold Inactive/hot Inactive/cold System stopped Reference Chapter 4 Preparing for Maintenance...
  • Page 76 Table 4-8     Active/hot Active/cold Inactive/hot Inactive/cold System stopped Reference Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 77 Chapter 5 Understanding the Preparations for Enabling Maintenance ■ ■ ■ ■ ■ Caution - Releasing an FRU from the System with the replacefru Command 5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the system ■ ■...
  • Page 78 12     /BB#11                             Unmount               ------------------------------------------------------------------------------ Select   [1-12|c:cancel]   : 1 Select the FRU requiring maintenance by specifying it with a numeric key. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 79 ------------------------------------------------------------------------------ Maintenance/Replacement   Menu Please   select   the   BB   or   a   type   of   FRU   to   be   replaced.   1.   BB   itself 2.   FAN                 (Fan   Unit) 3.
  • Page 80   2     /XBBOX#81                       Degraded   ------------------------------------------------------------------------------ Select   [1,2|c:cancel]   : 2 Select the FRU requiring maintenance by specifying it with a numeric key. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 81 ------------------------------------------------------------------------------ Maintenance/Replacement   Menu Please   select   a   type   of   FRU   to   be   replaced.   1.   FAN                 (Fan   Unit) 2.   PSU                 (Power   Supply   Unit) 3.
  • Page 82                   active           -n----     5002         16         8G               7.3%     2h   54m Execute the ldm list-devices -a command to check the usage status of the resource. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 83 #   ldm list-devices -a CORE         ID             %FREE       CPUSET           0               0               (0,   1)  ...
  • Page 84 /BB1/PCI7                                                                   PCIE       PCIE11       Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 85: Powering Off The Physical Partition Requiring Maintenance

    /BB1/PCI8                                                                   PCIE       PCIE11       Execute the showboards command to check the state of the chassis requiring maintenance.
  • Page 86 01-0   00(01)               Assigned         y         y         y         Passed     Normal Execute the poweroff command to stop all the logical domains on the physical partition requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 87: Stopping The Entire System

    XSCF>   poweroff -p 0 PPAR-IDs   to   power   off:00 Continue?   [y|n]   : y 00   :   Powering   off Execute the showpparstatus command to confirm that the power to the physical partition is turned off. XSCF>   showpparstatus -p 0 PPAR-ID  ...
  • Page 88: Stopping The System With The Xscf Command

    00   :   Powering   off 01   :   Powering   off Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Check that the POWER LED on the operation panel is off. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 89: Stopping The System From The Operation Panel

    Note - 5.4.2 Stopping the system from the operation panel Switch the mode switch on the operation panel to Service mode. Note - Press the power switch on the operation panel for 4 seconds or more. Note - Check that the POWER LED on the operation panel is off. Note - Accessing Components 5.5.1...
  • Page 90: Removing The Power Cord

    Figure 5-1     Lower the cable support.   5.5.2 Removing the power cord Release the latch (A in the figure) of the cable clamp.   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 91   Figure 5-2     Figure 5-3     Remove the power cord of the SPARC M10-4S from the PSU backplane unit, or remove the power cord of the crossbar box from the power supply unit. Chapter 5 Understanding the Preparations for Enabling Maintenance...
  • Page 92: Removing The Front Cover

    Figure 5-4     Figure 5-5     5.5.3 Removing the front cover Release the right and left slide locks of the front cover and pull it towards the front. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 93 Figure 5-6     Figure 5-7     Lift the front cover upwards to remove it. Chapter 5 Understanding the Preparations for Enabling Maintenance...
  • Page 94   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 95 ■ ■ ■ Incorporating an FRU into the System with the replacefru Command 6.1.1 Incorporating an FRU of the SPARC M10-4/M10- 4S into the system ■ ■ ■ After completing maintenance of the target FRU, return to the replacefru command operation of the XSCF firmware, and enter "f".
  • Page 96 PSB     Test         Fault ----   -------   -------- 00-0   Passed     Normal     done Confirm that the status is normal ("Normal") after the replacement, and then enter "f". Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 97 ------------------------------------------------------------------------------ Maintenance/Replacement   Menu Status   of   the   replaced   FRU.   FRU                                   Status                 -------------------  ...
  • Page 98: Incorporating A Chassis Into A Physical Partition

    Select   [1,2|c:cancel]   : c Incorporating a Chassis into a Physical Partition Log in to the XSCF shell. Execute the addboard command to incorporate the target chassis into the physical partition. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 99 Note XSCF>   addboard -c configure -p 0 01-0 PSB#01-0   will   be   configured   into   PPAR-ID   0.   Continue?[y|n]   : y Start   connecting   PSB   to   PPAR.   [3600sec] 0..  30..  60..  90..120..150..180..210..240..270..300..330..360..390..420..450..480..510..
  • Page 100 If there is a guest domain that uses a virtual device, log in to the guest domain to restart the use of the device or incorporate it into the duplication function again. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 101: Powering On The Physical Partition Requiring Maintenance

    Powering On the Physical Partition Requiring Maintenance Switch the mode switches of the master chassis and those chassis whose XSCFs are in the standby state to Locked mode. For a building block configuration (without crossbar box) For a building block configuration (with crossbar box) Log in to the XSCF shell.
  • Page 102: Starting The Entire System

                    +   FRU-Part-Number:CA07361-D202   A0                                                   ;                   +   Power_Supply_System:   ;                   +   Memory_Size:320   GB; Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 103: Starting The System With An Xscf Command

                                            +   Model:; ------------------------ Ommitted ----------------------- Start the entire system. ■ ■ Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide 6.4.1 Starting the system with an XSCF command Execute the poweron command. XSCF>   poweron -a PPAR-IDs  ...
  • Page 104: Restoring The Chassis

    Connect the power cord of the SPARC M10-4S to the PSU backplane unit, or connect the power cord of the crossbar box to the power supply unit. Figure 6-1     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 105 Figure 6-2     Clip the cable clamp around the power cord and then fix the cable clamp. Figure 6-3     Chapter 6 Understanding the Preparations for Restoring the System...
  • Page 106: Fixing The Cable Support

    Figure 6-4     6.5.2 Fixing the cable support Lift the cable support and lock it in place by pushing the upper and lower screw fittings towards the back (direction of the arrow). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 107: Installing The Front Cover

    Figure 6-5     Tighten the right and left screws to fix the cable support.   Note - 6.5.3 Installing the front cover To install the front cover, insert the tabs of the front cover into the notches at Chapter 6 Understanding the Preparations for Restoring the System...
  • Page 108 Figure 6-6     Figure 6-7     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 109 Note - Chapter 6 Understanding the Preparations for Restoring the System...
  • Page 110 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 111 Chapter 7 Maintaining the CPU Memory Units ■ ■ ■ ■ ■ ■ ■ ■ Configuration of the CPU Memory Units...
  • Page 112 Figure 7-1     Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 113: Before Maintaining A Cpu Memory Unit

    Figure 7-2     Before Maintaining a CPU Memory Unit Note - 7.2.1 Types of maintenance Chapter 7 Maintaining the CPU Memory Units...
  • Page 114: Maintenance Flow

    Table 7-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Building block configuration 7.2.2 Maintenance flow Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 115: Precautions For Replacement

    Table 7-2     Task Lower unit Upper unit Upper unit Upper unit replacement replacement expansion reduction Switching the microSD card 7.2.3 Precautions for replacement ■ ■ ■ ■ Chapter 7 Maintaining the CPU Memory Units...
  • Page 116: Precautions For Installation

    ■ 7.2.4 Precautions for installation ■ ■ ■ ■ function=mod 7.2.5 Precautions for removal ■ ■ function=mode Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 117 Enabling the Removal of a CPU Memory Unit Note - ■ ■ ■ Caution - 7.3.1 Active/Cold maintenance Note - Note - Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance.
  • Page 118 Note - Confirm the hardware and software configurations. Power off the physical partition requiring maintenance. Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 119: System-Stopped Maintenance

    Log in to the XSCF shell. Execute the dumpconfig command to back up the XSCF setting information when replacing the CPU memory unit lower. Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide XSCF>   dumpconfig Execute the showlogs command to identify the component requiring maintenance.
  • Page 120 Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 121: Removing A Cpu Memory Unit

    Removing a CPU Memory Unit Caution - 7.4.1 Accessing a CPU memory unit Remove the crossbar cables from the cable support. Procedure when equipment rack model 26xx is used Remove all the crossbar cables from the crossbar unit. Note - Remove the hook-and-loop fastener of the cable support (A in the figure) to which the crossbar cables are fixed.
  • Page 122 180 degrees. Figure 7-4     Use the hook-and-loop fastener to fix the crossbar cables to the cable holder. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 123 Figure 7-5     Procedure when equipment rack model 16xx is used Remove all the crossbar cables from the crossbar unit. Note - Remove the hook-and-loop fastener of the cable support (A in the figure) to which the crossbar cables are fixed. Figure 7-6  ...
  • Page 124 Note - Remove all the PCIe card cassettes. Note - If any crossbar units are mounted, remove them. Loosen the three screws holding the mounting frame and then remove it. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 125: Removing A Cpu Memory Unit From The Chassis

    Figure 7-8     7.4.2 Removing a CPU memory unit from the chassis Note - Loosen the one screw securing the lever of the CPU memory unit (rear left side) and then lower the right and left levers of the CPU memory unit to the horizontal position.
  • Page 126: Removing The Cpu Memory Unit Upper

    7.4.3 Removing the CPU memory unit upper Unlock (push) the top cover of the CPU memory unit and remove the cover by sliding it in the direction of the arrow. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 127 Figure 7-11     Unlock (push) the right-side guide and remove it by sliding it in the direction of the arrow. Figure 7-12     Unlock (push) the left-side guide (when viewed from the rear) and remove it Chapter 7 Maintaining the CPU Memory Units...
  • Page 128 Figure 7-14     Remove the two PCIe cables (A in the figure) on the left side that connect the CPU memory units upper and lower, from the CPU memory unit upper. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 129 Figure 7-15     Of the two PCIe cables on the left side, also remove the rear one from the CPU memory unit lower, as it is short. Chapter 7 Maintaining the CPU Memory Units...
  • Page 130 Figure 7-16     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 131 Figure 7-17     Raise the levers (A in the figure) on the right and left sides to release the CPU memory unit upper. Chapter 7 Maintaining the CPU Memory Units...
  • Page 132 If PCIe cables are connected to the CPU memory unit lower that has a filler unit mounted, move the PCIe cables (A and B in the figure) further apart toward the outside of the chassis. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 133 Figure 7-19     Lift the CPU memory unit upper or filler unit, and then remove it carefully. Note - Note - Chapter 7 Maintaining the CPU Memory Units...
  • Page 134: Installing A Pci Express Cable

    Installing a PCI Express cable Note - Note - Remove the eight screws at both ends of the XSCF cable connection port on the rear of the CPU memory unit lower. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 135 Figure 7-21     Loosen the two screws holding the upper rear side of the CPU memory unit lower. Then, remove the rear cover (A in the figure) by pulling it in the direction of the arrow. Chapter 7 Maintaining the CPU Memory Units...
  • Page 136 Figure 7-22     Remove the XSCF board. For the SPARC M10-4 with a FRAME-A CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 137 Figure 7-23     For the SPARC M10-4S with a FRAME-A CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 138 Figure 7-24     Pull out the XSCF board diagonally to the right (arrow). Note - Figure 7-25     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 139 Figure 7-26     Remove the screw fixing the XSCF mount. For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 140 Figure 7-27     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 141 Figure 7-28     For the SPARC M10-4S with a FRAME-B CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 142 Figure 7-29     Remove the XSCF mount. For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 143 Figure 7-30     Chapter 7 Maintaining the CPU Memory Units...
  • Page 144 Figure 7-31     For the SPARC M10-4S with a FRAME-B CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 145 Figure 7-32     Remove the screw fixing the CPU memory unit board. For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 146 Figure 7-33     For SPARC M10-4S with a FRAME-B CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 147 Figure 7-34     Place your thumb on the frame located at the center of the right and left sides of the CPU memory unit board (A in the figure) and insert your fingers under the CPU memory unit board (B in the figure) from the side of the connector unit.
  • Page 148 Figure 7-36     Right Left Supporting the frame with your thumb (A in the figure), disconnect the connection of the connector by pushing up the left and right sides at the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 149 same time with the fingers that are inserted under the CPU memory unit board (B in the figure). Figure 7-37     Place your thumb on the connector unit located at the center of the right and left sides of the CPU memory unit board (A in the figure) and hold the board by inserting your fingers under the CPU memory unit board (B in the figure) from the side of the connector unit.
  • Page 150 Figure 7-38     Left Right Figure 7-39     Right Left Lift the CPU memory unit board in the horizontal position and remove it from the frame. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 151 Figure 7-40     Remove the sheet (A in the figure).   Chapter 7 Maintaining the CPU Memory Units...
  • Page 152 Figure 7-41     Remove the three PCIe cables. Note - The connectors for the three PCIe cables facing the outside of the CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 153 Figure 7-42     The connector for one PCIe cable facing the outside of the CPU memory unit and the other two facing the front of the CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 154 PCIBP board (A in the figure). Note - Note - The connectors for the three PCIe cables facing the outside of the CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 155 Figure 7-44     The connector for one PCIe cable facing the outside of the CPU memory unit and the other two facing the front of the CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 156 Figure 7-45     Install the sheet (A in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 157 Figure 7-46     Hold the connector unit at the center of the CPU memory unit board and install it on the frame in the horizontal position. Note - Chapter 7 Maintaining the CPU Memory Units...
  • Page 158 Figure 7-47     Figure 7-48     For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 159 Figure 7-49     For the SPARC M10-4S with a FRAME-B CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 160 Figure 7-50     Fix the CPU memory unit board with screws. For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 161 For the SPARC M10-4S with a FRAME-B CPU memory unit Install the XSCF mount and fix it with screws. For the SPARC M10-4/M10-4S with a FRAME-A CPU memory unit Figure 7-51     For the SPARC M10-4S with a FRAME-B CPU memory unit...
  • Page 162 Figure 7-52     Install the XSCF board. For the SPARC M10-4 with FRAME-A CPU memory unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 163 Figure 7-53     For the SPARC M10-4S with FRAME-A CPU memory unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 164 Figure 7-54     Attach the rear cover with two screws from the upper part of the rear side of the CPU memory unit lower. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 165 Figure 7-55     Install the eight screws at both ends of the XSCF cable connection port on the rear of the CPU memory unit lower. Chapter 7 Maintaining the CPU Memory Units...
  • Page 166: Switching The Microsd Card

    Switching the microSD Card Remove the screw of the microSD card protective tape (A in the figure) that is fixed on the removed CPU memory unit lower, and then remove the protective tape. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 167 Figure 7-57     Push in the microSD card slightly with your finger and then release it. Pull out the microSD card horizontally. Chapter 7 Maintaining the CPU Memory Units...
  • Page 168 Insert the microSD card that was removed in step 3 into the microSD card slot of the new CPU memory unit lower. Then, push it in with a finger until it locks in place. Note - Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 169: Installing A Cpu Memory Unit

    Figure 7-59     Attach the microSD card protective tape, and tighten the screw. Note - Installing a CPU Memory Unit Chapter 7 Maintaining the CPU Memory Units...
  • Page 170: Installing The Cpu Memory Unit Upper

    When installing a filler unit for the CPU memory unit lower connected with PCIe cables, move the PCIe cables (A and B in the figure) further apart toward the outside of the chassis. Note - Note - Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 171 Figure 7-60     Install the CPU memory unit upper or filler unit on the CPU memory unit lower. When installing the CPU memory unit upper Note - Chapter 7 Maintaining the CPU Memory Units...
  • Page 172 Figure 7-61     When installing a filler unit   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 173 Figure 7-62     Install the CPU memory unit upper by holding it down from the center where the label "PUSH" is applied, and then push it into place. Chapter 7 Maintaining the CPU Memory Units...
  • Page 174 Figure 7-63     Connect, to the CPU memory unit upper, the four right and left PCIe cables connecting the CPU memory units upper and lower. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 175 Note - If a filler unit for the CPU memory unit upper has been installed, hold the packaging material (A and B in the figure) of the PCIe cable connector part over the top of the left- and right-side guides (C and D in the figure). Figure 7-64  ...
  • Page 176 Figure 7-65     Figure 7-66     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 177 Figure 7-67     Chapter 7 Maintaining the CPU Memory Units...
  • Page 178 Figure 7-68     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 179 Figure 7-69     Chapter 7 Maintaining the CPU Memory Units...
  • Page 180 Figure 7-70     Unlock (push) the top cover of the CPU memory unit and install the top cover by sliding it. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 181: Installing The Cpu Memory Unit In The Chassis

    7.7.2 Installing the CPU memory unit in the chassis Install the CPU memory unit upper or a filler unit for a CPU memory unit upper. Insert the CPU memory unit into the chassis while supporting it from below with one hand. Raise the right and left levers of the CPU memory unit to secure it.
  • Page 182: Restoring The System

    Connect all the crossbar cables to the crossbar unit. Use the hook-and-loop fastener to fix the crossbar cables to the cable support. Note - Restoring the System Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 183 Note - ■ ■ ■ 7.8.1 Active/Cold maintenance Note - Note - Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system.
  • Page 184 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 185 XSCF>   showlogs error Power on the physical partition requiring maintenance. Close the rack door. When the system is configured with a hardware RAID Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system.
  • Page 186: System-Stopped Maintenance

    Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Execute the diagxbu command to diagnose the crossbar cables.   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 187 Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide XSCF>   restoreconfig Execute the version command to confirm the firmware version information. Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide XSCF>   version -c xcp -v BB#00-XSCF#0   (Master) XCP0   (Current):   2011 CMU  ...
  • Page 188 Execute the showdate command to confirm the XSCF time. XSCF>   showdate If the XSCF time is different from the current time, execute the setdate command to set the time. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 189   XSCF>   setdate -s 102016592013.00 Start the entire system. Close the rack door. When the system is configured with a hardware RAID Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system.
  • Page 190 XSCF                     :   02.01.0001 CMU   BACKUP #0:   02.01.0001 #1:   .. XSCF> Execute the showlogs command to confirm that the system is operating normally. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 191 XSCF>   setpparmode -p 0 -m guestboot=off Start the entire system. The ok prompt appears. Enable the RAID volume to check the status. Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Execute the setpparmode command to activate the Autoboot function of the guest domain.
  • Page 192 Execute the showdate command to confirm the XSCF time. XSCF>   showdate If the XSCF time is different from the current time, execute the setdate command to set the time.   XSCF>   setdate -s 102016592013.00 Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 193: Memory Configuration

    Chapter 8 Maintaining the Memory ■ ■ ■ ■ ■ ■ ■ Memory Configuration...
  • Page 194 (2) (1) (4) (3) (10) (9) (12) (11) CPU#1 (27) (28) (25) (26) (19) (20) (17) (18) (22) (21) (24) (23) (30) (29) (32) (31) Front Location number Component Group Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 195 Location number Component Group Chapter 8 Maintaining the Memory...
  • Page 196 (34) (33) (36) (35) (42) (41) (44) (43) CPU#1 (59) (60) (57) (58) (51) (52) (49) (50) (54) (53) (56) (55) (62) (61) (64) (63) Front Location number Component Group Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 197: Memory Configuration Rules

    Location number Component Group Memory Configuration Rules Chapter 8 Maintaining the Memory...
  • Page 198: Memory Mounting Rules

    8.2.1 Memory mounting rules ■ ■ ■ ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 199 Figure 8-3     CMUL CPU#0 CPU#1 Front CMUU CPU#0 CPU#1 Front Chapter 8 Maintaining the Memory...
  • Page 200 Table 8-2     Number of Mounted memory memory modules When expanding a CPU memory unit upper to a chassis in which only a CPU memory unit lower is mounted Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 201: Checking Memory Information

    Table 8-3     Number of Mounted memory memory modules 8.2.2 Checking memory information Log in to the XSCF shell. Execute the showhardconf command to check the memory information. XSCF> showhardconf ------------------------ Ommitted ------------------------         MBU   Status:Normal;   Ver:2086h;   Serial:TZ1249M00C     ;  ...
  • Page 202 09: R-DIMM (32GB 4rank) 47: LR-DIMM (64GB 8rank) Before Maintaining Memory Note - 8.3.1 Types of maintenance Table 8-4     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 203: Maintenance Flow

    Table 8-4     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Building block configuration 8.3.2 Maintenance flow Table 8-5     Details of update process Replacement Expansion Reduction 8.3.3 Precautions for replacement ■ 8.3.4 Precautions for installation ■ ■ Chapter 8 Maintaining the Memory...
  • Page 204 Active/Cold maintenance Note - Note - Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 205 Note - Confirm the hardware and software configurations. Release from the physical partition the chassis in which the memory requiring maintenance is mounted. Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance.
  • Page 206: System-Stopped Maintenance

    XSCF>   showlogs error Note - Confirm the hardware and software configurations. Stop the entire system. Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 207: Removing Memory

    Removing Memory Caution - 8.5.1 Accessing memory Perform the preparations that must be completed prior to removing the CPU memory unit. Remove the CPU memory unit. 8.5.2 Removing memory Open the clip of the memory slot outwards and remove the memory by pulling it straight up.
  • Page 208: Installing Memory

    Installing memory Place the memory module by aligning the notched section with the corresponding part of the memory slot connector. Push the memory module into the slot evenly. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 209: Restoring The Chassis

    8.6.2 Restoring the chassis Install the CPU memory unit Restore the chassis. Restoring the System Note - ■ ■ ■ 8.7.1 Active/Cold maintenance Note - Note - Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance.
  • Page 210 Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 211 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Power on the physical partition requiring maintenance. Close the rack door. 8.7.3 System-stopped maintenance Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance.
  • Page 212 Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 213 Chapter 9 Maintaining the Crossbar Units ■ ■ ■ ■ ■ ■ Configuration of the Crossbar Units...
  • Page 214 Figure 9-1     Location number Component Before Maintaining a Crossbar Unit Note - 9.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 215 Table 9-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 9.2.2 Maintenance flow Table 9-2     Details of update process Replacement Enabling the Removal of a Crossbar Unit ■ ■ Caution - 9.3.1 Inactive/Cold maintenance Open the rack door.
  • Page 216 XSCF>   showlogs error Confirm the hardware and software configurations. Stop the entire system. Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 217: Removing A Crossbar Unit

    Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - Removing a Crossbar Unit Caution - 9.4.1 Accessing a crossbar unit Lower the cable support. Note - Remove all the crossbar cables connected to the crossbar units requiring maintenance.
  • Page 218 Figure 9-2     Open the eject levers (A in the figure) upwards and downwards, respectively, and then pull the crossbar unit out of the CPU memory unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 219: Installing A Crossbar Unit

    Figure 9-3     Support the crossbar unit from below with one hand and carefully remove it from the mounting frame. Note - Installing a Crossbar Unit Note - Chapter 9 Maintaining the Crossbar Units...
  • Page 220 Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 221 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Switch the mode switches of the master chassis and those chassis whose XSCFs are in the standby state to Locked mode.
  • Page 222 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Start the entire system. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 223 Chapter 10 Maintaining the Power Supply Units ■ ■ ■ ■ ■ ■ 10.1 Configuration of the Power Supply Units...
  • Page 224 Figure 10-1     Location number Component 10.2 Before Maintaining a Power Supply Unit Note - 10.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 225 Table 10-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Building block configuration 10.2.2 Maintenance flow Table 10-2     Details of update process Replacement 10.2.3 Precautions for replacement ■ ■ ■ Chapter 10 Maintaining the Power Supply Units...
  • Page 226 Execute the showlogs command to identify the component requiring maintenance. XSCF> showlogs error Confirm the hardware and software configurations. Execute the replacefru command to release the power supply unit requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 227 10.3.2 Inactive/Hot maintenance For a single-chassis configuration Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Stop the entire system. Execute the showpparstatus command to confirm that the physical partition requiring maintenance is powered off.
  • Page 228 Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 229: Removing A Power Supply Unit

    Note - 10.3.4 System-stopped maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Stop the entire system. Execute the replacefru command to release the chassis requiring maintenance from the system.
  • Page 230: Accessing A Power Supply Unit

    Hold the lever and pull the power supply unit out of the chassis. Support the power supply unit from below with one hand and remove it carefully from its slot. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 231: Installing A Power Supply Unit

    Note - 10.5 Installing a Power Supply Unit 10.5.1 Installing a power supply unit Support the power supply unit from below with one hand and insert it carefully into its slot. Note - Firmly push the power supply unit into its mounting position. Close the lever and then tighten the screws.
  • Page 232 For a building-block configuration Log in to the XSCF shell. Return to the operation of the XSCF firmware replacefru command to confirm that the power supply unit has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 233 Power on the physical partition requiring maintenance. Close the rack door. 10.6.3 Inactive/Cold maintenance Note - Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system.
  • Page 234 Start the entire system. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 235: Maintaining The Fan Units

    Chapter 11 Maintaining the Fan Units ■ ■ ■ ■ ■ ■ 11.1 Configuration of the Fan Units...
  • Page 236 Figure 11-1     Location number Component 11.2 Before Maintaining a Fan Unit Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 237: Types Of Maintenance

    11.2.1 Types of maintenance Table 11-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Building block configuration 11.2.2 Maintenance flow Table 11-2     Details of update process Replacement 11.2.3 Precautions for replacement ■ ■ Chapter 11 Maintaining the Fan Units...
  • Page 238 Execute the showlogs command to identify the component requiring maintenance. XSCF> showlogs error Confirm the hardware and software configurations. Execute the replacefru command to release the fan unit requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 239 11.3.2 Inactive/Hot maintenance For a single-chassis configuration Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Stop the entire system. Execute the showpparstatus command to confirm that the physical partition requiring maintenance is powered off.
  • Page 240 Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 241: Removing A Fan Unit

    11.3.4 System-stopped maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Stop the entire system. Execute the replacefru command to release the chassis requiring maintenance from the system.
  • Page 242: Accessing A Fan Unit

    Caution - 11.4.1 Accessing a fan unit Remove the front cover. 11.4.2 Removing a fan unit Pull out the fan unit while raising its lever. Figure 11-2     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 243: Installing A Fan Unit

    Carefully remove the fan unit from its slot. Note - 11.5 Installing a Fan Unit 11.5.1 Installing a fan unit Carefully insert the fan unit into its slot. Note - Push the fan unit fully home. Note - 11.5.2 Restoring the chassis Install the front cover.
  • Page 244 For a building-block configuration Log in to the XSCF shell. Return to the operation of the XSCF firmware replacefru command to confirm that the fan unit has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 245 Power on the physical partition requiring maintenance. Close the rack door. 11.6.3 Inactive/Cold maintenance Note - Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system.
  • Page 246 Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 247: Maintaining The Internal Disks

    Chapter 12 Maintaining the Internal Disks ■ ■ ■ ■ ■ ■ 12.1 Configuration of the Internal Disks...
  • Page 248 Figure 12-1     Location number Component 12.1.1 Identification of disk slot     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 249 For Oracle Solaris 11 For Oracle Solaris 10 Using the format command (Oracle Solaris 11) Execute the showhardconf command to confirm the CMUL serial number of the chassis that indicates the mounting position information. XSCF> showhardconf SPARC   M10-4S;         +   Serial:2081238017;   Operator_Panel_Switch:Service;  ...
  • Page 250               /pci@8800/pci@4/pci@0/pci@0/scsi@0/iport@f/disk@w50000394281b5312,0               /dev/chassis/FUJITSU-BBEXP.500000e0e06d31bf/03N0_HDD00/disk   <--   (2)                                                                                                       *   The   last   four   digits   of  ...
  • Page 251                         +   FRU-Part-Number:CA07361-D941   C3       /7060911                             ;                         +   Memory_Size:128   GB;  ...
  • Page 252 Enclosure   path:                   /dev/es/ses0 Chassis   Serial   Number:     500000e0e06d233f Chassis   Model:                     FUJITSU-BBEXP Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 253   Label         Disk   name                               Vendor       Product                 Vers --------   ----------------------     --------   --------------   ---- HDD_0  ...
  • Page 254 01-0     00(01)                 Assigned           y           y           y           Passed       Normal 12.2 Before Maintaining an Internal Disk Note - 12.2.1 Types of maintenance Table 12-2     Configuration Active/hot Active/hot (with DR) Inactive/hot System stopped 12.2.2 Maintenance flow Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 255 Table 12-3     Details of update process Replacement Expansion Reduction 12.2.3 Precautions for installation ■ ■ 12.2.4 Precautions for removal ■ 12.3 Enabling the Removal of an Internal Disk Note - ■ ■ ■ ■ Chapter 12 Maintaining the Internal Disks...
  • Page 256 Execute the cfgadm(1M) command to check the configuration of the internal disk. #   cfgadm -a Stop all applications from using the internal disk. Execute the cfgadm(1M) command to release the internal disk requiring maintenance from the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 257 #   cfgadm -c unconfigure  Ap_ID Execute the cfgadm(1M) command to blink the CHECK LED of the internal disk requiring maintenance, and determine its location. #   cfgadm -x led=fault,mode=blink  Ap_ID Execute the cfgadm(1M) command to confirm that the internal disk requiring maintenance is disconnected. #  ...
  • Page 258: Removing An Internal Disk

    Open the rack door. Confirm the hardware and software configurations. Stop the entire system. 12.4 Removing an Internal Disk Caution - 12.4.1 Accessing an internal disk Remove the front cover. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 259 12.4.2 Removing an internal disk Push the knob on the internal disk to unlock it and then raise the lever to a 45-degree angle. Figure 12-2     Hold the lever and pull out the internal disk by about 3 cm (1.2 in.) Note - Chapter 12 Maintaining the Internal Disks...
  • Page 260: Installing An Internal Disk

    Installing an Internal Disk 12.5.1 Installing an internal disk When expanding an internal disk, remove the internal disk filler unit from the slot in which the disk is to be installed. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 261: Restoring The Chassis

    Install the front cover. 12.6 Restoring the System Note - ■ ■ ■ ■ 12.6.1 Active/Hot maintenance When the system is configured with a hardware RAID Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Chapter 12 Maintaining the Internal Disks...
  • Page 262 Active/hot maintenance (with DR) Execute the testsb command to confirm that the internal disk requiring maintenance is recognized. XSCF>   testsb -v -y -p 00-0 Incorporate the chassis, in which the internal disk requiring maintenance is Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 263 mounted, into the physical partition. Close the rack door. 12.6.3 Inactive/Hot maintenance Log in to the XSCF shell. Execute the testsb command to confirm that the internal disk requiring maintenance is recognized. XSCF>   testsb -v -y -s 00-0 Power on the physical partition requiring maintenance. Close the rack door.
  • Page 264   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 265: Maintaining The Pci Express Cards

    Chapter 13 Maintaining the PCI Express Cards ■ ■ ■ ■ ■ ■ ■ 13.1 Configuration of the PCI Express Cards...
  • Page 266 Figure 13-1     (1) (2) (4) (5) (6) (7) (10) (11) Location Component number Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 267 13.2 Before Maintaining a PCI Express Card Note - 13.2.1 Types of maintenance Table 13-1     Configuration Active/hot (with PHP) Active/hot (with DR) Inactive/hot System stopped 13.2.2 Maintenance flow Chapter 13 Maintaining the PCI Express Cards...
  • Page 268: Precautions For Replacement

    Table 13-2     Details of update process Replacement Expansion Reduction 13.2.3 Precautions for replacement ■ 13.2.4 Precautions for installation ■ ■ ■ 13.2.5 Precautions for removal ■ ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 269 13.3 Checking If PCI Hot Plug (PHP) Can Be Used Log in to the XSCF shell. Execute the showlogs command to identify the PCIe card requiring maintenance. XSCF> showlogs error Confirm the hardware and software configurations. Check whether the PCIe card requiring maintenance supports PHP. If the PCIe card requiring maintenance supports PHP, execute the ldm list-io -l command to confirm the logical domain to which the PCIe card is assigned and the logical domain to which the PCIe root complex the PCIe card belongs...
  • Page 270 /BB0/PCI10                                                                 PCIE       PCIE7         primary     OCC [pci@8700/pci@4/pci@0/pci@11] Logical domain to which the PCIe card is assigned Logical domain to which the PCIe root complex the PCIe card belongs to is assigned Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 271 Determine whether PHP can be used, combining the two pieces of information described above based on the confirmation results obtained in step 5. Figure 13-2     Assign a PCIe endpoint device to I/O domain *5 to *8 in the figure correspond to the above ldm list-io -l command execution example. Table 13-3  ...
  • Page 272 System configuration Operation Reference Single-chassis configuration "13.4.4 System-stopped maintenance" 13.4 Enabling the Removal of a PCI Express Card ■ ■ ■ ■ 13.4.1 Active/hot maintenance (with PHP) Open the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 273: Network Switch

    Connect to the control domain console of the physical partition. Check whether there is any guest domain that is virtually using the PCIe card requiring maintenance.   For an Ethernet card Execute the ldm list-bindings <domain name> command from the control domain to check virtual network switch [VSW] information for the physical network interface name ([NET-DEV] value) that is assigned to a virtual network switch.
  • Page 274 Then, identify the PCIe card in use from the physical disk. case, execute the zfs list command to confirm the ZFS storage pool corresponding zpool name Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 275 If the virtual disk service to which the PCIe card requiring maintenance is assigned is found in steps a and b, see the [CLIENT] part for the virtual disk service displayed in step a. Confirm the virtual disk and guest domain to which the backend of the virtual disk service is assigned.
  • Page 276 Execute the cfgadm -x command to cause the ATTENTION LED on the PCIe card cassette requiring maintenance to blink. #   cfgadm -x led=attn,mode=blink  Ap_Id 13.4.2 Active/hot maintenance (with DR) Note - Note - Open the rack door. Confirm the hardware and software configurations. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 277 Release from the physical partition the chassis in which the PCIe card requiring maintenance is mounted. Referencing step 5 in "13.3 Checking If PCI Hot Plug (PHP) Can Be Used," confirm the logical domains to which the PCIe root complex and PCIe slot of the chassis with the maintenance target mounted are assigned.
  • Page 278: Removing A Pci Express Card

    Power off the physical partition requiring maintenance. 13.4.4 System-stopped maintenance Open the rack door. Confirm the hardware and software configurations. Stop the entire system. 13.5 Removing a PCI Express Card Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 279 Caution - 13.5.1 Accessing a PCI Express card cassette Lower the cable support. Note - Remove the cables connected to the PCIe card cassette requiring maintenance. Note - 13.5.2 Removing a PCI Express card cassette Figure 13-3     Type-1 Type-2 Lower the lever (B in the figure) of the PCIe card cassette while pushing the Chapter 13 Maintaining the PCI Express Cards...
  • Page 280 (A in the figure). Figure 13-4     Hold the lever and carefully pull the PCIe card cassette out of the PCI slot to remove it. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 281 Figure 13-5     13.5.3 Removing a PCI Express card Remove the cover while pushing the clip (A in the figure) at the rear of the cover. Figure 13-6     Remove the screw securing the PCIe card cassette. Chapter 13 Maintaining the PCI Express Cards...
  • Page 282 Figure 13-7     Remove the bracket (A in the figure) from the PCIe card. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 283 Figure 13-8     Remove the PCIe card from the PCIe card cassette. Note - Note - Chapter 13 Maintaining the PCI Express Cards...
  • Page 284: Installing A Pci Express Card

    Figure 13-9     13.6 Installing a PCI Express Card 13.6.1 Installing a PCI Express card Install the PCIe card by inserting it into the connector of the PCIe card cassette. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 285 Figure 13-10     Install the bracket for the PCIe card, and secure it with the screw. Figure 13-11     Chapter 13 Maintaining the PCI Express Cards...
  • Page 286: Installing A Pci Express Card Cassette

    Raise the lever of the PCIe card cassette while pushing the latch and secure Note - 13.6.3 Restoring the chassis Connect the cables to the PCIe card cassette. Note - Lift the cable support to fix it. 13.7 Restoring the System Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 287 Note - ■ ■ ■ ■ 13.7.1 Active/hot maintenance (with PHP) Display the Oracle Solaris super-user prompt. Execute the cfgadm -c command to start the power supply to the PCIe card requiring maintenance. #   cfgadm -c connect  Ap_Id Execute the cfgadm -c command to incorporate the PCIe card requiring maintenance into the logical domain.
  • Page 288 Power on the physical partition requiring maintenance. Close the rack door. 13.7.4 System-stopped maintenance Log in to the XSCF shell. Execute the testsb command to confirm that the PCIe card requiring maintenance is recognized. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 289 XSCF>   testsb -v -y -s 00-0 Start the entire system. Close the rack door. Chapter 13 Maintaining the PCI Express Cards...
  • Page 290   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 291 Chapter 14 Maintaining the PSU Backplane Unit ■ ■ ■ ■ ■ ■ 14.1 Location of the PSU Backplane Unit Caution -...
  • Page 292 Figure 14-1     Location Component number 14.2 Before Maintaining the PSU Backplane Unit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 293 Note - 14.2.1 Types of maintenance Table 14-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Building block configuration 14.2.2 Maintenance flow Table 14-2     Details of update process Replacement 14.3 Enabling the Removal of the PSU Backplane Unit Chapter 14 Maintaining the PSU Backplane Unit...
  • Page 294 Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 295 Note - 14.3.2 Inactive/Cold maintenance Note - Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Power off the physical partition requiring maintenance. Execute the replacefru command to release the chassis requiring maintenance from the system.
  • Page 296: Removing The Psu Backplane Unit

    XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - 14.4 Removing the PSU Backplane Unit Caution - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 297 14.4.1 Accessing the PSU backplane unit Lower the cable support. Remove all the cables connected to the external interface. ■ ■ ■ ■ ■ Note - Remove all PCIe card cassettes. Note - Remove all the crossbar units. Note - Loosen the three screws securing the mounting frame of the crossbar unit and then remove the frame.
  • Page 298 Remove all the fan units. Note - Remove all the internal disks or the HDD filler units. Note - Loosen the two screws in the fan slot and then remove the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 299 Figure 14-4     14.4.2 Removing the PSU backplane unit Loosen the two screws securing the PSU backplane unit and then partially pull out the PSU backplane unit. Figure 14-5     Pull the PSU backplane unit out a little more. Then, remove the unit by holding its handle.
  • Page 300: Installing The Psu Backplane Unit

    Install the operation panel on the PSU backplane unit. Insert the PSU backplane unit into the chassis by holding the handle. Tighten the two screws securing the PSU backplane unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 301: Restoring The Chassis

    14.5.2 Restoring the chassis Install the fan shelf and then tighten the two screws in the fan slot. Install all the power supply units. Note - Install all the fan units. Note - Install all the internal disks or HDD filler units. Note - Install the front cover.
  • Page 302: Restoring The System

    Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 303 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -p 02 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Incorporate the chassis, in which the PSU backplane unit requiring maintenance is mounted, into the physical partition. Close the rack door.
  • Page 304 Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Execute the diagxbu command to diagnose the crossbar cables. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 305   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Start the entire system. Close the rack door. Chapter 14 Maintaining the PSU Backplane Unit...
  • Page 306   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 307 Chapter 15 Maintaining the Operation Panel ■ ■ ■ ■ ■ ■ 15.1 Location of the Operation Panel...
  • Page 308 Figure 15-1     Location number Component 15.2 Before Maintaining the Operation Panel Note - 15.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 309 Table 15-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) System stopped Single-chassis configuration Building block configuration 15.2.2 Maintenance flow Table 15-2     Details of update process Replacement 15.2.3 Precautions for replacement ■ 15.3 Enabling the Removal of the Operation Panel Note - ■...
  • Page 310 Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 311 15.3.2 Inactive/Cold maintenance Note - Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Power off the physical partition requiring maintenance. Execute the replacefru command to release the chassis requiring maintenance from the system.
  • Page 312: Removing The Operation Panel

    15.4 Removing the Operation Panel Caution - 15.4.1 Accessing the operation panel Check the BB-ID switch on the operation panel and record the BB-ID set for the chassis requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 313 Lower the cable support. Remove all the cables connected to the external interface. ■ ■ ■ ■ ■ Note - Remove all PCIe card cassettes. Note - Remove all the crossbar units. Note - Loosen the three screws securing the mounting frame of the crossbar unit and then remove the frame.
  • Page 314 Pull out the power supply unit by about 10 cm (3.9 in.) Remove all the fan units. Note - Loosen the two screws in the fan slot and then remove the fan shelf. Figure 15-4     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 315 15.4.2 Removing the operation panel Loosen the two screws securing the PSU backplane unit and partially pull out the PSU backplane unit. Figure 15-5     Remove the cable from the operation panel and loosen one screw (A in the figure).
  • Page 316: Installing The Operation Panel

    Install the front cover. Note - Insert the CPU memory unit into the chassis. Raise the right and left levers of the CPU memory unit and then tighten the one screw. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 317: Restoring The System

    Install the mounting frame for the crossbar unit and then tighten the three screws. Note - Install all the crossbar units. Install all the PCIe card cassettes. Note - Connect all the cables to the external interface. ■ ■ ■ ■...
  • Page 318 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Incorporate the chassis, in which the operation panel requiring maintenance is mounted, into the physical partition. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 319 15.6.2 Inactive/Cold maintenance Note - Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Execute the diagxbu command to diagnose the crossbar cables.
  • Page 320 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Start the entire system. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 321 Chapter 16 Maintaining the Crossbar Units of the Crossbar Box ■ ■ ■ ■ ■ ■ 16.1 Configuration of the Crossbar Units...
  • Page 322 Figure 16-1     Location Component number 16.2 Before Maintaining a Crossbar Unit Note - 16.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 323 Table 16-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 16.2.2 Maintenance flow Table 16-2     Details of update process Replacement 16.3 Enabling the Removal of a Crossbar Unit Caution - Open the rack door. Log in to the XSCF shell.
  • Page 324 Remove all crossbar cables (optical) connected to the crossbar unit requiring maintenance. Note - Loosen the two screws (A in the figure) on the right and left sides and lower the levers to release the crossbar unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 325 Figure 16-2     Hold the levers and partially pull out the crossbar unit. Chapter 16 Maintaining the Crossbar Units of the Crossbar Box...
  • Page 326: Installing A Crossbar Unit

    Note - 16.5 Installing a Crossbar Unit Note - Carefully insert the crossbar unit into the chassis. Close the right and left levers of the crossbar unit and tighten two screws. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 327 Connect all crossbar cables (optical) to the crossbar unit. Note - 16.6 Restoring the System Turn on the CB switches of the dedicated power distribution unit (PDU) mounted on the rack for expanded connection. Execute the diagxbu command to diagnose the crossbar cables.  ...
  • Page 328   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 329 Chapter 17 Maintaining the XSCF Unit of the Crossbar Box ■ ■ ■ ■ ■ ■ 17.1 Location of the XSCF Unit...
  • Page 330 Figure 17-1     Location Component number 17.2 Before Maintaining the XSCF Unit Note - 17.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 331 Table 17-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 17.2.2 Maintenance flow Table 17-2     Details of update process Replacement 17.3 Enabling the Removal of the XSCF Unit ■ ■ Caution - 17.3.1 Active/Hot maintenance Open the rack door.
  • Page 332 XSCF>   showlogs error Confirm the hardware and software configurations. Power off all the physical partitions. Execute the replacefru command to release the XSCF unit requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 333: Removing The Xscf Unit

    Remove all the power cords from the power supply unit of the crossbar box requiring maintenance. Note - 17.4 Removing the XSCF Unit Caution - Remove all the cables connected to the maintenance-target XSCF unit. ■ ■ ■ Note - Note - Loosen the two screws (A in the figure) of the XSCF unit and lower the right and left levers to release the XSCF unit.
  • Page 334 Figure 17-2     Hold the levers and partially pull out the XSCF unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 335: Installing The Xscf Unit

    Figure 17-3     Support the XSCF unit from below with one hand and then remove it carefully. Note - 17.5 Installing the XSCF Unit Note - Carefully insert the XSCF unit into the chassis. Raise the right and left levers and then tighten the two screws. Reconnect all the cables to the XSCF unit.
  • Page 336 Execute the switchscf command to switch the standby XSCF to the master XSCF. XSCF>   switchscf -t Active Close the rack door. 17.6.2 System-stopped maintenance Connect all the power cords to the power supply unit of the crossbar box requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 337 Note - Return to the operation of the XSCF firmware replacefru command to confirm that the XSCF unit has been incorporated into the system. Start all the physical partitions. Close the rack door. Chapter 17 Maintaining the XSCF Unit of the Crossbar Box...
  • Page 338   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 339 Chapter 18 Maintaining the Power Supply Units of the Crossbar Box ■ ■ ■ ■ ■ ■ 18.1 Configuration of the Power Supply Units...
  • Page 340 Figure 18-1     Location Component number 18.2 Before Maintaining a Power Supply Unit Note - 18.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 341 Table 18-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 18.2.2 Maintenance flow Table 18-2     Details of update process Replacement 18.2.3 Precautions for replacement ■ ■ ■ 18.3 Enabling the Removal of a Power Supply Unit Chapter 18 Maintaining the Power Supply Units of the Crossbar Box...
  • Page 342 Remove the power cord from the power supply unit requiring maintenance. 18.3.2 System-stopped maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 343: Removing A Power Supply Unit

    XSCF>   showlogs error Confirm the hardware and software configurations. Power off all the physical partitions. Execute the replacefru command to release the power supply unit requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the power supply unit of the crossbar box requiring maintenance.
  • Page 344 Installing a Power Supply Unit Support the power supply unit from below with one hand and insert it carefully into its slot. Note - Push the power supply unit fully home. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 345 Note - 18.6 Restoring the System ■ ■ 18.6.1 Active/Hot maintenance Connect the power cords to the power supply unit requiring maintenance. Confirm that the LED (green) of the power supply unit is on. Return to the operation of the XSCF firmware replacefru command to confirm that the power supply unit has been incorporated into the system.
  • Page 346 Return to the operation of the XSCF firmware replacefru command to confirm that the power supply unit has been incorporated into the system. Power on all the physical partitions. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 347 Chapter 19 Maintaining the Fan Units of the Crossbar Box ■ ■ ■ ■ ■ ■ 19.1 Configuration of the Fan Units...
  • Page 348 Figure 19-1     Location Component number 19.2 Before Maintaining a Fan Unit Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 349 19.2.1 Types of maintenance Table 19-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 19.2.2 Maintenance flow Table 19-2     Details of update process Replacement 19.2.3 Precautions for replacement ■ ■ 19.3 Enabling the Removal of a Fan Unit Chapter 19 Maintaining the Fan Units of the Crossbar Box...
  • Page 350 System-stopped maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 351: Removing A Fan Unit

    Power off all the physical partitions. Execute the replacefru command to release the fan unit requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the power supply unit of the crossbar box requiring maintenance. Note - 19.4 Removing a Fan Unit Caution -...
  • Page 352 Note - 19.5 Installing a Fan Unit 19.5.1 Installing a fan unit Carefully insert the fan unit into its slot. Note - Push the fan unit fully home. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 353: Restoring The Chassis

    19.5.2 Restoring the chassis Install the front cover.   19.6 Restoring the System ■ ■ 19.6.1 Active/Hot maintenance Return to the operation of the XSCF firmware replacefru command to confirm that the fan unit has been incorporated into the system. Execute the showstatus command to confirm that the fan unit is operating normally after maintenance.
  • Page 354 Return to the operation of the XSCF firmware replacefru command to confirm that the fan unit has been incorporated into the system. Power on all the physical partitions. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 355 Chapter 20 Maintaining the XSCF Interface Unit of the Crossbar Box ■ ■ ■ ■ ■ ■ 20.1 Location of the XSCF Interface Unit...
  • Page 356 Figure 20-1     Location Component number 20.2 Before Maintaining the XSCF Interface Unit Note - 20.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 357 Table 20-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 20.2.2 Maintenance flow Table 20-2     Details of update process Replacement 20.3 Enabling the Removal of the XSCF Interface Unit Caution - Open the rack door. Log in to the XSCF shell.
  • Page 358 XSCF interface unit. Note - Loosen the two screws (A in the figure) of the XSCF interface unit and lower the right and left levers to release the XSCF interface unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 359 Figure 20-2     Hold the levers and partially pull out the XSCF interface unit. Figure 20-3     Support the XSCF interface unit from below with one hand and then carefully remove it from the chassis. Chapter 20 Maintaining the XSCF Interface Unit of the Crossbar Box...
  • Page 360 Restoring the System Turn on the CB switches of the dedicated power distribution unit (PDU) mounted on the rack for expanded connection. Start the entire system. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 361 Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box ■ ■ ■ ■ ■ ■ 21.1 Location of the Crossbar Backplane Unit...
  • Page 362 Figure 21-1     Location Component number 21.2 Before Maintaining the Crossbar Backplane Unit Note - 21.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 363 Table 21-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 21.2.2 Maintenance flow Table 21-2     Details of update process Replacement 21.3 Enabling the Removal of the Crossbar Backplane Unit Caution - Open the rack door. Log in to the XSCF shell.
  • Page 364 Loosen the two screws (A in the figure) securing the upper cover and slide the right and left stoppers (B in the figure) inwards. Then, remove the upper cover (C in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 365 Figure 21-2     Loosen the one screw (A in the figure) securing the lower cover and then slide the lower cover to the left to remove it. Figure 21-3     Disconnect the two cables from the fan shelf. Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box...
  • Page 366 Place a hand under the fan shelf to support it and then carefully remove it from the chassis. Note - Note - Loosen the two screws and remove the bracket (B in the figure) fixing the guide plate (A in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 367 Figure 21-6     Slide the guide plate (A in the figure) to the front to remove it. Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box...
  • Page 368 Figure 21-7     Remove the cable from the clamps. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 369 Figure 21-8       Loosen the five screws securing the crossbar backplane unit and then pull the crossbar backplane unit straight out by holding the center handle (A in the figure). Note - Note - Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box...
  • Page 370 Insert the crossbar backplane unit into the chassis and then tighten the five screws. Fix the cables of the crossbar backplane unit with the clamps. Install the guide plate by sliding it towards the rear and then tighten the two screws. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 371 Support the fan shelf from below with one hand and then insert it carefully into the chassis. Tighten the three screws securing the fan shelf. Connect the two cables to the fan shelf. Install the lower cover and then secure it with the one screw. Install the upper cover.
  • Page 372 XSCF>   diagxbu -y -b 00 -p 02 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Start the entire system. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 373 Chapter 22 Maintaining the Fan Backplane of the Crossbar Box ■ ■ ■ ■ ■ ■ 22.1 Configuration of the Fan Backplane...
  • Page 374 Figure 22-1     Location Component number 22.2 Before Maintaining the Fan Backplane Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 375 22.2.1 Types of maintenance Table 22-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 22.2.2 Maintenance flow Table 22-2     Details of update process Replacement 22.3 Enabling the Removal of the Fan Backplane Caution - Open the rack door.
  • Page 376: Removing The Fan Backplane

    Removing the fan backplane Loosen the two screws (A in the figure) securing the upper cover and then slide the right and left stoppers (B in the figure) inwards. Then, remove the Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 377 upper cover (C in the figure). Figure 22-2     Loosen the one screw (A in the figure) securing the lower cover and then slide the lower cover to the left to remove it. Figure 22-3     Disconnect the two cables from the fan shelf. Chapter 22 Maintaining the Fan Backplane of the Crossbar Box...
  • Page 378 Place a hand under the fan shelf to support it and then carefully remove it from the chassis. Note - Note - Disconnect the two cables from the fan backplane.   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 379 Figure 22-6     Remove the two screws securing the fan backplane to remove the bracket (A in the figure). Chapter 22 Maintaining the Fan Backplane of the Crossbar Box...
  • Page 380: Installing The Fan Backplane

    Connect the two cables to the fan backplane. Support the fan shelf from below with one hand and then insert it carefully into the chassis. Tighten the three screws securing the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 381: Restoring The Chassis

    Connect the two cables to the fan shelf. Install the lower cover and then secure it with the one screw. Install the upper cover. Slide the right and left stoppers of the upper cover outwards and then secure the cover with the two screws. 22.5.2 Restoring the chassis Install all the fan units.
  • Page 382   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 383 Chapter 23 Maintaining the Operation Panel of the Crossbar Box ■ ■ ■ ■ ■ ■ 23.1 Location of the Operation Panel...
  • Page 384 Figure 23-1     Location Component number 23.2 Before Maintaining the Operation Panel Note - 23.2.1 Types of maintenance Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 385 Table 23-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 23.2.2 Maintenance flow Table 23-2     Details of update process Replacement 23.2.3 Precautions for replacement ■ 23.3 Enabling the Removal of the Operation Panel Caution - Open the rack door.
  • Page 386: Removing The Operation Panel

    Loosen the two screws (A in the figure) securing the upper cover and then slide the right and left stoppers (B in the figure) inwards. Then, remove the upper cover (C in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 387 Figure 23-2     Loosen the one screw (A in the figure) securing the lower cover and then slide the lower cover to the left to remove it. Figure 23-3     Disconnect the two cables from the fan shelf. Chapter 23 Maintaining the Operation Panel of the Crossbar Box...
  • Page 388 Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Figure 23-5     Place a hand under the fan shelf to support it and then carefully remove it from the chassis. Note - Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 389 23.4.2 Removing the operation panel Remove the cable connecting the fan shelf to the operation panel. Figure 23-6     Front Loosen the one screw securing the operation panel and then remove it. Chapter 23 Maintaining the Operation Panel of the Crossbar Box...
  • Page 390: Installing The Operation Panel

    Figure 23-7     Front Note - 23.5 Installing the Operation Panel Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 391 23.5.1 Installing the operation panel Set the BB-ID of the operation panel to the value prior to the start of maintenance. Insert the operation panel into the fan shelf and then secure it with the screw. Figure 23-8     Front Reinstall the cable between the fan shelf and the operation panel.
  • Page 392 Install the lower cover and then secure it with the one screw Install the upper cover and slide the right and left stoppers outwards. Then, tighten the two screws to secure the upper cover. Install all the fan units. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 393 Install the front cover of the crossbar box. 23.6 Restoring the System Turn on the CB switches of the dedicated power distribution unit (PDU) mounted on the rack for expanded connection. Start the entire system. Close the rack door. Chapter 23 Maintaining the Operation Panel of the Crossbar Box...
  • Page 394   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 395 Chapter 24 Maintaining the Crossbar Cables (Electrical) ■ ■ ■ ■ ■ ■ 24.1 Configuration of the Ports for the Crossbar Cables (Electrical)    ...
  • Page 396 Figure 24-1     XBU#0 XBU#1 Figure 24-2     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 397 Location Component number 24.2 Before Maintaining a Crossbar Cable (Electrical) Note - 24.2.1 Types of maintenance Table 24-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped 24.2.2 Maintenance flow Table 24-2     Task Replacement Chapter 24 Maintaining the Crossbar Cables (Electrical)
  • Page 398 XSCF> showlogs error Confirm the hardware and software configurations. Power off the physical partition requiring maintenance. Execute the replacefru command to release the chassis requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 399: System-Stopped Maintenance

    Remove all the power cords from the PSU backplane unit of the chassis requiring maintenance. Note - 24.3.2 System-stopped maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>...
  • Page 400 24.4 Removing a Crossbar Cable (Electrical) Caution - Remove the two crossbar cables (electrical) from the SPARC M10-4S. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 401 Figure 24-3     Remove the two crossbar cables (electrical) from the other chassis. 24.5 Installing a Crossbar Cable (Electrical) Attach the supplied connection destination label to the new replacement crossbar cable (electrical). Connect a pair of crossbar cables (electrical) to each chassis. Chapter 24 Maintaining the Crossbar Cables (Electrical)
  • Page 402 Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 403 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Power on the physical partition requiring maintenance. Close the rack door. 24.6.2 System-stopped maintenance Connect all the power cords to the PSU backplane unit of the chassis requiring maintenance.
  • Page 404 Power on all the physical partitions. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 405 Chapter 25 Maintaining the Crossbar Cables (Optical) ■ ■ ■ ■ ■ ■ 25.1 Configuration of the Ports for the Crossbar Cables (Optical)
  • Page 406 L6 L7 R2 R3 R6 R7 L2 L3 L6 L7 R2 R3 R6 R7 L2 L3 L6 L7 R2 R3 R6 R7 L2 L3 L6 L7 R2 R3 R6 R7 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 407 Figure 25-3     Figure 25-4     Location Component number Chapter 25 Maintaining the Crossbar Cables (Optical)
  • Page 408 25.2.1 Types of maintenance Table 25-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped 25.2.2 Maintenance flow Table 25-2     Task Replacement 25.2.3 Precautions for replacement ■ ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 409 ■ 25.3 Enabling the Removal of a Crossbar Cable (Optical) ■ ■ Caution - 25.3.1 Inactive/Cold maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF> showlogs error Confirm the hardware and software configurations.
  • Page 410 Execute the replacefru command to release the SPARC M10-4S requiring maintenance from the system. XSCF>   replacefru Remove all the power cords from the SPARC M10-4S power supply unit requiring maintenance. Note - 25.4 Removing a Crossbar Cable (Optical) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 411 Caution - Remove the two crossbar cables (optical) from the SPARC M10-4S. Figure 25-5     Remove the other pair of crossbar cables (optical) from the crossbar box. Chapter 25 Maintaining the Crossbar Cables (Optical)
  • Page 412 Attach the supplied connection destination label to the new replacement crossbar cable (optical). Connect a pair of crossbar cables (optical) to the SPARC M10-4S and the crossbar box. Note - Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 413 Figure 25-7     Number in Description figure Note - Note - 25.6 Restoring the System ■ ■ 25.6.1 Inactive/Cold maintenance Connect all power cords to the SPARC M10-4S power supply unit requiring maintenance. Chapter 25 Maintaining the Crossbar Cables (Optical)
  • Page 414 Connect all power cords to the SPARC M10-4S power supply unit requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that SPARC M10-4S has been incorporated into the system. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 415 Execute the diagxbu command to diagnose the crossbar cables.   XSCF>   diagxbu -y -b 00 -t 01 Execute the showlogs command to confirm that the system is operating normally. XSCF>   showlogs error Power on all the physical partitions. Close the rack door. Chapter 25 Maintaining the Crossbar Cables (Optical)
  • Page 416   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 417 Chapter 26 Maintaining the XSCF BB Control Cables ■ ■ ■ ■ ■ ■ 26.1 Configuration of the Ports for the XSCF BB Control Cables    ...
  • Page 418 Figure 26-1     Figure 26-2     Location Component number Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 419 26.2 Before Maintaining an XSCF BB Control Cable Note - 26.2.1 Types of maintenance Table 26-1     Cable connection destinations Active/hot Active/cold Inactive/hot Inactive/cold System stopped 26.2.2 Maintenance flow Table 26-2     Task Replacement Chapter 26 Maintaining the XSCF BB Control Cables...
  • Page 420 Execute the switchscf command to switch the master XSCF to a standby XSCF. XSCF>   switchscf -t Standby Execute the replacefru command to release the XSCF unit of the crossbar box requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 421 26.3.2 Active/Cold maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Release the chassis connected to the XSCF BB control cable requiring maintenance from the physical partition.
  • Page 422 For maintenance on the XSCF BB control cable connected to the SPARC M10-4S requiring maintenance, execute the replacefru command to release this SPARC M10-4S from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 423: Removing An Xscf Bb Control Cable

    Remove all the power cords from the PSU backplane unit or power supply unit of the chassis requiring maintenance. Note - 26.4 Removing an XSCF BB Control Cable Caution - Remove the XSCF BB control cable from the SPARC M10-4S or the crossbar box.
  • Page 424 Figure 26-3     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 425: Installing An Xscf Bb Control Cable

    Figure 26-4     Remove the XSCF BB control cables from the other chassis. 26.5 Installing an XSCF BB Control Cable Attach the supplied connection destination label to the new replacement XSCF BB control cable. Connect the XSCF BB control cable to SPARC M10-4S or the crossbar box. Chapter 26 Maintaining the XSCF BB Control Cables...
  • Page 426: Restoring The System

    Execute the showhardconf command to check the hardware configuration and the status of each component. XSCF>   showhardconf Execute the switchscf command to switch the standby XSCF to the master XSCF. XSCF>   switchscf -t Active Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 427 26.6.2 Active/Cold maintenance Connect all the power cords to the PSU backplane unit or power supply unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that SPARC M10-4S has been incorporated into the system. Incorporate the chassis connected to the XSCF BB control cable requiring maintenance into the physical partition.
  • Page 428 Return to the operation of the XSCF firmware replacefru command to confirm that SPARC M10-4S has been incorporated into the system. Power on all the physical partitions. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 429 Chapter 27 Maintaining the XSCF DUAL Control Cables ■ ■ ■ ■ ■ ■ 27.1 Configuration of the XSCF DUAL Control Ports    ...
  • Page 430 Figure 27-1     Figure 27-2     Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 431 27.2 Before Maintaining an XSCF DUAL Control Cable Note - 27.2.1 Types of maintenance Table 27-1     Cable connection destinations Active/hot Active/cold Inactive/hot Inactive/cold System stopped 27.2.2 Maintenance flow Table 27-2     Task Replacement Chapter 27 Maintaining the XSCF DUAL Control Cables...
  • Page 432 Execute the switchscf command to switch the master XSCF to a standby XSCF. XSCF>   switchscf -t Standby Execute the replacefru command to release the XSCF unit of the crossbar box requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 433 27.3.2 Active/Cold maintenance Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF>   showlogs error Confirm the hardware and software configurations. Release the chassis connected to the XSCF DUAL control cable requiring maintenance from the physical partition.
  • Page 434 For maintenance on the XSCF DUAL control cable connecting one SPARC M10-4S to another, execute the replacefru command to release the SPARC M10-4S requiring maintenance from the system. XSCF>   replacefru Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 435: Removing An Xscf Dual Control Cable

    Remove all the power cords from the PSU backplane unit or power supply unit of the chassis requiring maintenance. Note - 27.4 Removing an XSCF DUAL Control Cable Caution - Remove the XSCF DUAL control cables from the SPARC M10-4S or the crossbar box.
  • Page 436 Figure 27-3     Figure 27-4     Remove the XSCF DUAL control cables from the other chassis. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 437: Installing An Xscf Dual Control Cable

    27.5 Installing an XSCF DUAL Control Cable Attach the supplied connection destination label to the replacement XSCF DUAL control cable. Connect the XSCF DUAL control cable to SPARC M10-4S or the crossbar box. Note - 27.6 Restoring the System ■ ■...
  • Page 438 Execute the showhardconf command to check the hardware configuration and the status of each component. XSCF>   showhardconf Incorporate the chassis connected to the XSCF DUAL control cable requiring maintenance into the physical partition. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 439 27.6.3 Inactive/Cold maintenance Connect all the power cords to the PSU backplane unit or power supply unit of the chassis requiring maintenance. Note - Return to the operation of the XSCF firmware replacefru command to confirm that SPARC M10-4S has been incorporated into the system. Power on the physical partition requiring maintenance.
  • Page 440   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 441 Chapter 28 Maintaining the Cable Kit of the Crossbar Box ■ ■ ■ ■ ■ ■ 28.1 Configuration of the Cable Kit 28.1.1 Cables for the connection between the crossbar backplane unit and terminal board ■...
  • Page 442 Figure 28-1     Location number Component ■ Figure 28-2     Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 443 28.1.2 Cables for the connection between the terminal board and fan backplane ■ Figure 28-3     Location number Component ■ Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 444 Figure 28-4     Location number Component 28.1.3 Locations for the cable kit Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 445 Figure 28-5     Location Component Connection number 28.2 Before Maintaining the Cable Kit Note - 28.2.1 Types of maintenance Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 446 Caution - Open the rack door. Log in to the XSCF shell. Execute the showlogs command to identify the component requiring maintenance. XSCF> showlogs error Confirm the hardware and software configurations. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 447 Stop the entire system. Turn off the circuit breaker switches (CB switches) of the dedicated power distribution unit (PDU) mounted on the rack for expanded connection. 28.4 Removing the Cable Kit Caution - 28.4.1 Removing the cables for the connection between the crossbar backplane unit and terminal board Remove the front cover.
  • Page 448 Loosen the one screw (A in the figure) securing the lower cover and then slide the lower cover to the left to remove it. Figure 28-7     Disconnect the two cables from the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 449 Figure 28-8     Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Figure 28-9     Place a hand under the fan shelf to support it and then carefully remove it from the chassis. Note - Note - Remove the cable connected to the crossbar backplane unit from the connector.
  • Page 450 Figure 28-10     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 451 Figure 28-11     Remove the cable from the clamps. Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 452 Loosen the two screws (A in the figure) securing the upper cover and then slide the right and left stoppers (B in the figure) inwards. Then, remove the upper cover (C in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 453 Figure 28-13     Loosen the one screw (A in the figure) securing the lower cover and then slide the lower cover to the left to remove it. Figure 28-14     Disconnect the two cables from the fan shelf. Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 454 Place a hand under the fan shelf to support it and then carefully remove it from the chassis. Note - Note - Remove the cable connecting the fan backplane from the connector. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 455 Figure 28-17     Figure 28-18     Remove the cable connecting the fan shelf and operation panel from the Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 456 Figure 28-19     Front Remove the cable from the terminal board. ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 457 Figure 28-20     ■ Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 458 Figure 28-21     Remove the cable from the clamps. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 459 Figure 28-22     Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 460 Figure 28-23     28.5 Installing the Cable Kit 28.5.1 Installing a cable between the crossbar backplane unit and terminal board Connect the cable to the connector of the crossbar backplane unit.   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 461   Figure 28-24     Secure the cable with a clamp. Support the fan shelf from below with one hand and then insert it carefully into the chassis. Tighten the three screws securing the fan shelf. Connect the two cables to the fan shelf. Install the lower cover and then secure it with the one screw.
  • Page 462 Figure 28-25     ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 463 Figure 28-26     Connect the cable to the connector of the fan backplane. Connect the cable connecting the fan shelf and operation panel to the connector on the operation panel. Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 464 Figure 28-27     Front Secure the cable with a clamp. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 465 Figure 28-28     Chapter 28 Maintaining the Cable Kit of the Crossbar Box...
  • Page 466 Install the upper cover. Slide the right and left stoppers of the upper cover outwards and then secure the cover with the two screws. Install all the fan units. Install the front cover. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 467: Restoring The System

    28.6 Restoring the System Turn on the CB switches of the dedicated power distribution unit (PDU) mounted on the rack for expanded connection. Execute the diagxbu command to diagnose the crossbar cables. When the system board of the chassis connected with the crossbar cables is not incorporated into the physical partition, or when the incorporated physical partition is powered off: XSCF>...
  • Page 468   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 469 Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection ■ ■ ■ ■ ■ ■ 29.1 Configuration of the Dedicated Power Distribution Unit...
  • Page 470 Figure 29-1     Rear Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 471 29.1.1 CB switches on the dedicated power distribution unit Figure 29-2     REAR Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection...
  • Page 472: Power Distribution Unit

    Types of maintenance Table 29-1     Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block configuration 29.2.2 Maintenance flow Table 29-2     Task Replacement 29.2.3 Precautions for replacement ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 473 ■ 29.3 Enabling the Removal of the Dedicated Power Distribution Unit ■ ■ 29.3.1 Active/Cold maintenance Caution - Open the rack door. Disconnect all the power cords of the SPARC M10-4S and crossbar boxes from the PDU requiring maintenance. Note - 29.3.2 System-stopped maintenance Open the rack door.
  • Page 474 29.4 Removing the Dedicated Power Distribution Unit Caution - Caution - Remove the four PDU screws. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 475 Figure 29-3     Grasp the top and bottom of the PDU, and then pull it out. Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection...
  • Page 476 Figure 29-4     Disconnect all the power cables from the rear of the PDU. Note - Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 477 Figure 29-5     For a single-phase power feed: Figure 29-6     For a three-phase power feed: Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection...
  • Page 478 For a single-phase power feed: For a three-phase power feed Note - Install the PDU into the rack for expanded connection. Install the four PDU screws. 29.6 Restoring the System ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 479 ■ 29.6.1 Active/Cold maintenance Connect all the power cords of the SPARC M10-4S and crossbar boxes to the PDU requiring maintenance. Note - Close the rack door. 29.6.2 System-stopped maintenance Connect all the power cords of the SPARC M10-4S and crossbar boxes to the PDU requiring maintenance.
  • Page 480   Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 481: Component List

    Appendix A Component List Figure A-1     (15) (14) (13) (12) (11) (10)
  • Page 482 Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 483 Figure A-2     (14) (13) (12) (11) (10) Location number Component Appendix A Component List...
  • Page 484 Location number Component Figure A-3     Rear Location number Component Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 485: Component Specifications

    Appendix B Component Specifications Components that constitute the SPARC M10-4/M10-4S ■ ■ ■ ■ ■ ■ ■ ■ Components that constitute the crossbar box ■ ■ ■ ■ ■ ■ ■ CPU Memory Unit...
  • Page 486: Crossbar Unit

    ■ ■ ■ ■ ■ ■ Table B-1     Item Description Crossbar Unit Table B-2     Item Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 487 Table B-2     Item Description Table B-3     Item Description XSCF Unit ■ ■ ■ ■ ■ ■ ■ ■ Table B-4     Item Description Appendix B Component Specifications...
  • Page 488: Power Supply Unit

    Table B-4     Item Description Power Supply Unit Table B-5     Item Description Table B-6     Item Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 489: Internal Disk Drive

    Fan Unit Table B-7     Item Description Table B-8     Item Description Internal Disk Drive Table B-9     Item Description Appendix B Component Specifications...
  • Page 490: Pci Express Card

    Table B-9     Item Description PCI Express Card Table B-10     Item Description XSCF Interface Unit Table B-11     Item Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 491 Table B-11     Item Description Backplanes   ■ Appendix B Component Specifications...
  • Page 492 Figure B-1     Table B-12     Item Description ■ ■ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 493 Figure B-2     Table B-13     Item Description Table B-14     Item Description Appendix B Component Specifications...
  • Page 494: Operation Panel

    Table B-14     Item Description B.10 Operation Panel Table B-15     Item Description Table B-16     Item Description Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 495: Oracle Solaris Troubleshooting Commands

    Appendix C Oracle Solaris Troubleshooting Commands ■ ■ ■ ■ ■ ■ ■ iostat(1M) Command Table C-1 Option Description Application...
  • Page 496 Media   Error:   0   Device   Not   Ready:   0   No   Device:   0   Recoverable:   0 Illegal   Request:   0   Predictive   Failure   Analysis:   0 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 497: Prtdiag(1M) Command

    Table C-2     Option Description Application #   prtdiag -v System   Configuration:     Oracle   Corporation     sun4v   SPARC   M10-4 Memory   size:   64000   Megabytes     ================================   Virtual   CPUs   ================================  ...
  • Page 498 /BB0/PCI0                   PCIE     QLGC,qlc-pciex1077,8001                       QLE8152         5.0GTx4                                                 /pci@8100/pci@4/pci@0/pci@0/pci@0/pci@0/pci@0/pci@1/ Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 499 pci@0/pci@0/QLGC,qlc@0,2 /BB0/PCI0                   PCIE     QLGC,qlc-pciex1077,8001                       QLE8152         5.0GTx4                                                 /pci@8100/pci@4/pci@0/pci@0/pci@0/pci@0/pci@0/pci@1/ pci@0/pci@0/QLGC,qlc@0,3 /BB0/PCI0  ...
  • Page 500: Prtconf(1M) Command

                    SUNW,asr   (driver   not   attached)                 kbd-translator   (driver   not   attached) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 501                 obp-tftp   (driver   not   attached)                 zfs-file-system   (driver   not   attached)                 hsfs-file-system   (driver   not   attached)  ...
  • Page 502                         pci,   instance   #107                                 pci,   instance   #108 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 503: Netstat(1M) Command

                                    pci,   instance   #109         pci-performance-counters,   instance   #0         pci-performance-counters,   instance   #1         pci-performance-counters,   instance   #2  ...
  • Page 504: Ping(1M) Command

        b0:99:28:98:30:36     local       REACHABLE         fe80::b299:28ff:fe98:3036 net0     33:33:ff:98:30:36     other       REACHABLE         ff02::1:ff98:3036   ping(1M) Command Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 505 hostname Table C-5     Option Description Application ping, and then displays the statistics. #   ping -s 10.24.187.50 PING   10.24.187.50:   56   data   bytes 64   bytes   from   10.24.187.50:   icmp_seq=0.   time=0.555   ms 64   bytes   from   10.24.187.50:   icmp_seq=1.   time=0.400   ms 64  ...
  • Page 506   0.0       508   /usr/lib/ssh/sshd   0.0       497   /usr/lib/fm/fmd/fmd   0.0       487   /usr/lib/hal/hald-addon-cpufreq   0.0       472   /usr/lib/autofs/automountd Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 507: Prstat(1M) Command

      0.0       470   /usr/lib/autofs/automountd   0.0       468   /usr/lib/inet/inetd   0.0       458   hald-runner   0.0       453   /usr/lib/hal/hald   0.0       450   /usr/sbin/rpcbind  ...
  • Page 508         13   root               20M       19M   sleep         59         0       0:00:37   0.0%   svc.configd/24 Total:   49   processes,   669   lwps,   load   averages:   0.05,   0.05,   0.04 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 509 Appendix D External Interface Specifications   ■ ■ ■ ■ ■ ■ Serial Port...
  • Page 510: Wire Connection Chart For Serial Cable

    Table D-1     Pin arrangement Signal Input/Output Description number name D.1.1 Wire connection chart for serial cable Figure D-1     USB Port Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 511: Reset Switch

    Table D-2     Pin arrangement Signal Input/Output Description number name SAS Port RESET Switch Fujitsu M10/SPARC M10 Systems System Operation and Administration Guide Appendix D External Interface Specifications...
  • Page 512 Figure D-2     Figure D-3     Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ February 2014...
  • Page 513 Index...