LUTControl
This section describes LUTControl category for the BG series.
This function allows you to apply the
● Registers
Register
Visibility
LUTSelector
Expert
LUTEnable
Expert
LUTIndex
LUTValue
● Setting
- Set the activation of LUT
Set the following value to "LUTEnable" register. The setting value is Boolean type.
- Set the input/output value of LUT
Set the following value to "LUTIndex", "LUTValue" registers. These setting values are Integer type.
"LUTIndex" register value is input level of LUT process, and "LUTValue" register value is output level of
LUT process.
● Note
Copyright © 2012 - 2013 TOSHIBA TELI CORPORATION, All rights reserved.
arbitrary
Access
R
Returns the luminance component of LUT process.
R/W
Sets the activation of LUT process.
Guru
R/W
Sets the input level of LUT process.
Guru
R/W
Sets the output level of LUT process.
setting value
FALSE (*)
TRUE
LUTIndex / LUTValue
Minimum (*)
Maximum
LUT(input: 10bit, output: 10bit) to the output images.
function
Inactivation
Activation
* initial factory setting
setting value
0
1023
* initial factory setting
73 / 85
Description
http://www.toshiba-teli.co.jp/index.htm