Diagnostic Indicator Display
There is a two-digit error code display located under horizontal output window near the vertical output window
(see figure below).
The following is a list of possible error codes and their meanings. Some errors will require immediate scanner
maintenance.
Error
Code
01
Reserved
RAM ERROR – The scanner's Random Access Memory (RAM) is tested as faulty. Return the unit
02
for repair at an authorized service center.
03
PROGRAM ERROR – The scanner's software program is failing. Return the unit for repair.
INTERFACE ERROR – After power up and any application exit (e.g. MetroSet, etc.), the scanner
checks the interface hardware with that chosen in configuration. If they do not agree, an interface
04
error exists. Correct this problem by getting the proper hardware interface OR programming
MS2420 configuration for the proper interface hardware attached.
CONFIGURATION ERROR – The non-volatile configuration memory did not agree with the data
last saved. Default configuration data is then used and the scanner continues operating. This error
05
is also accompanied by three beeps. This error will remain during operation as a reminder that this
power cycle is scanning against a default-generated configuration.
COMMUNICATION ERROR – The RS232 data line is being held active. This causes the scanner
to read a "break" signal constantly and continuous attempts are made to enter MetroSet
configuration mode. A short on the RX Data line can cause this condition. It can also be the result
06
of a laptop in power save mode. The scanner will abort attempts to enter configuration mode after
a short timeout. The scanner can automatically recover from this condition once the short in the
RX Data line is corrected.
36
Figure 28. Error Code Display (Optional Product Roll Bar Shown)