DIAGNOSIS & TROUBLESHOOTING
FAILURE/ERROR DISPLAY CODES
TECH SHEET 8522648, REV. A
• All diagnoses of this range must begin with a
normal check of the line voltage, blown fuses,
and failed components.
4-DIGIT
3-DIGIT
DISPLAY
DISPLAY
F0
E0
E0
E1
F1
E2
E4
E6
E0
F2
E1
E0
E1
E2
F3
E3
E4
E5
E6
F3
E7
F5
E0
F5
E1
F8
E0
LIKELY FAILURE
CONDITION
Factory default - not an error
EEPROM communications
error
EEPROM checksum error
UL A/D error(s)
Model ID error
Latch signal mismatch error
Shorted key
Key tail unplugged
Oven sensor opened - Top
Oven sensor shorted - Top
Bake range over temperature
Clean range over temperature
Oven sensor opened - Top
Oven sensor shorted - Top
Warming drawer sensor open
Warming drawer sensor shorted
Door switches do not agree
Door latch not operating
N/A
• All units that have failed during the first few
days of use, should be checked for loose
connections, or miswiring.
• All checks should be made with a meter
having a sensitivity of 20,000 ohms per volt,
or greater.
SUGGESTED
CORRECTIVE ACTION PROCEDURE
1. No action required.
1. Verify failure if not displayed, using
error code is displayed.
2. Disconnect power longer than 30 seconds.
3. Re-apply power and observe for longer than 1 minute.
4. If failure remains, disconnect power, replace control.
1. Verify failure if not displayed, using
2. Disconnect power.
3. If applicable, ensure membrane tail is seated in connector on back of control.
4. Re-apply power and observe for longer than 1 minute.
5. If failure remains, disconnect power, replace control.
1. Measure sensor value (between connector pins) between 1000
°
@ 900 F (room temperature approx. = 1080
real temperature, disconnect power, replace sensor and refer to steps 3-5.
Also measure from sensor connector to sensor casing for possible short.
2. Trace wires and connectors to sensor from control, then from sensor back to control. If
all connections are made and no wire damage, refer to step 3.
3. Disconnect power longer than 30 seconds.
4. Re-apply power and observe for longer than 1 minute.
5. If failure remains, disconnect power, replace control, then go back to step 4.
1. Same corrective action as for other F3 codes, with the exception that the warming
drawer resistance value at room temperature is approx. 100k
1. Disconnect power from unit.
2. Check wires and connectors from control to door switch, then from door switch to
control.
3. If no damage to wires or connector, replace door switch.
4. Re-apply power.
5. Press CANCEL PROGRAM and start the clean mode, and observe for one minute to
ensure that operation is normal.
1. Verify error code by pressing and holding CANCEL/OFF key for 5 seconds. Momentarily
(less than 5 sec.) press CANCEL key again to remove error code display.
2. Program and start the Clean mode. Observe to see if door locks. If it does not, inspect
the locking mechanism from the solenoid to the latch pawl and door to find the cause
of the problem. If the door is not locking, then 1 minute from the start of the Clean, the
F5 E1 code will again be displayed. Press CANCEL key to remove error code display.
3. Once any mechanical problems with the latch mechanism have been corrected, program
and start a Clean cycle (after, if necessary, clearing F5 E1 error code) to ensure proper
operation of the door lock. Immediately cancel the Clean mode to observe proper
operation of door unlock.
N/A
6-1
key. Press key for 5 seconds until last
CANCEL/OFF
key. Press for 5 seconds.
CANCEL/OFF
°
@ 32 F and 2697
). If measurement does not correlate to
.

Advertisement