Electrical: 115-volt, 60-Hz, AC-only, 15-amp
grounded circuit is required. A time-delay fuse or
circuit breaker and separate circuit is
recommended.
Water: A cold water supply using 1/4 in.
(0.64 cm) O.D. soft copper tubing with shutoff
valve.
Drain: Either a gravity-drain system or
condensate pump to carry water to an existing
drain.
CABINET OPENING DIMENSIONS
34"
(86.4 cm)
Min.
34
1/2
"
(87.6 cm)
Max.
(60.1 cm)
DRAIN REQUIREMENTS
A. Water Pan
Drain
B. Water Valve
(38.7 cm)
A
B
5
"
(14.5 cm)
17
(45.2 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®

Ice Maker

14
1/2
"
(36.8 cm)
(72.4 cm)
9"
1/2
3
"
(22.9 cm)
(8.9 cm)
24"
18"
(45.7 cm)
15 "
8
"
(22.4 cm)
2 "
(7.27 cm)
"
1. Recommended location for
electrical and plumbing fixtures.
2. Floor level
A
28
1/2
"
B
3 "
(9.2 cm)
1" (2.54 cm)
23"
(58.4 cm)
2" - 1 "
(5 cm - 3.8 cm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Drain lines must have a minimum of 5⁄8 in.
(15.88 mm) inside diameter.
Drain lines must have a 1 in. drop per 48 in. (2.54 cm
drop per 122 cm) of run or 1⁄4 in. drop per 12 in.
(6.35 mm per 30.48 cm) and must not have low
points where water can settle.
The floor drains must be large enough to
A
accommodate drainage from all drains.
B
The ideal installation has a standpipe with a 1-1⁄2 in.
(3.81 cm) to 2 in. (5.08 cm) PVC drain reducer
installed directly below the outlet of the drain tube as
shown. You must maintain a 1 in. (2.54 cm) air gap
between the drain hose and the standpipe.
C
It may be desirable to insulate the drain line
thoroughly up to the drain inlet.
D
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the ³⁄₄" (1.91 cm) panel on the door. The
drain should also be centered from left to right (8
[22.37 cm] from either side of the ice maker).