Download Print this page
American Standard CADET ELITE 2771E SERIES Installation Instructions

American Standard CADET ELITE 2771E SERIES Installation Instructions

5' x 36" whirlpool/bathing pool

Advertisement

Quick Links

CADET ELITE™
5' x 36"
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
305 mm
RECOMMENDED FITTING LOCATION
(12)
235 mm
(9-1/4)
19 mm
(3/4)
FINISHED
WALL
SEE FITTING
SPECS FOR
DIMENSIONS
229 mm
(9)
914 mm
(36)
CUTOUT IN FLOOR
457 mm
FOR DRAIN
(18)
C/L OF
57 mm
SUPPLIES
(2-1/4)
C/L OF DRAIN
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
38 mm
(1-1/2)
76 mm
(3)
502 mm
(19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
1-1/2 O.D.TAILPIECE
GENERAL SPECIFICATIONS FOR 2771E WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
PUMP
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
752860-100 Rev. B
2771E SERIES
WHIRLPOOL/BATHING POOL

INSTALLATION INSTRUCTIONS

PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
1524 mm
(60)
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ON/OFF
SWITCH
PUMP
(8) JETS
(2) AIR VALVES
OUTLINE OF CUTOUT
1486 mm x 876 mm
ALT. FITTING
(58-1/2 X 34-1/2)
LOCATION #1
C/L OF
SHOWER ARM
C/L OF
VALVES
C/L OF
305 mm
SPOUT
LEVELING
(12)
STRINGER
IN-LINE HEATER
102 mm
NOT FOR
REMOVABLE
(4)
BLANK
SUPPORT
464 mm
(18-1/4)
1-1/2 N.P.T.M.
THREADS
70 mm
(2-3/4)
117 mm
(4-5/8)
60 x 36 x 19-3/4 In.
(1524mm x 914 mm x 502mm)
95 Lbs. (43 Kg.)
587 Lbs. (267 Kg.)
59 Gal. (224 L.)
48 Gal. (182 L.)
40 x 22 In. (1016mm x 559mm)
52 x 29 In. (1321mm x 737mm)
13-1/4 In. (337mm)
39 Lbs./Sq. Ft. (188 Kgs/Sq. m.)
23.8
44.5
1.6 HP, 9.7 AMPS, 120V.

THANK YOU...

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
• Flex-Jet Soft Jet Kit*
• E-Z-Install Heater*
• Tile Bead Kit*
• Apron Kit*
List of Required Components (not included):
• Drain*
* see your Home Depot Retailer
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
© American Standard Inc. 2002
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
• Bath Filler*
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFI
Outlet
• Cement, Plaster,
Grout

Advertisement

loading

Summary of Contents for American Standard CADET ELITE 2771E SERIES

  • Page 1: Installation Instructions

    Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
  • Page 2 INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an access opening for servicing the pump and controls.
  • Page 3: Read And Follow All Instructions

    ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
  • Page 4 WIR E SELECTI ON G UID E Moto r Hi Per fo r mance Rating DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of the highest jet.