Your freezer needs air

Your freezer is designed for maintenance-free operation. What it
should never lack is good ventilation. Air is supplied under the ventila-
tion slot between the freezer and storage surface. Air is extracted
through the upper ventilation grille. Never obstruct these openings.

Electrical Connection

Any electrical work required to install this appliance should be carried
out by a qualified electrician or competent person.
WARNING – THIS APPLIANCE MUST BE EARTHED
The manufacturer declines any liability should these safety measures
not be observed.
Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance rating plate. The rating plate is
inside, on the left.
The appliance is supplied with a 13 amp plug fitted. In the event of
having to change the fuse in the plug supplied, a 13 amp ASTA
approved (BS 1362) fuse must be used.
Important
The wires in the mains lead are coloured in accordance with the
following code:
Green and YellowEarth
Blue Neutral
BrownLive
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings indentifying the terminals in
your plug, proceed as follows:
1.The wire coloured green and yellow must be connected to the
terminal marked with the letter „E" or by the earth symbol or coloured
green and yellow.
2.The wire coloured blue must be connected to the terminal „N" or
coloured black.
3.The wire coloured brown must be connected to the terminal marked
„L" or coloured red.
4.Upon completion there must be not cut, or stray strands of wire
present and the cord clamp must be secure over the outer sheat.