Chamberlain Liftmaster Professional SL595 Owner's Manual

Chamberlain Liftmaster Professional SL595 Owner's Manual

Heavy duty sliding gate operator gl controlled board
Hide thumbs Also See for Liftmaster Professional SL595:

Advertisement

GL
MODEL SL585
HEAVY DUTY SLIDE GATE OPERATOR
MODEL SL595
HEAVY DUTY, HARSH ENVIRONMENT
SLIDE GATE OPERATOR
2 YEAR WARRANTY
Serial # ________________________
(located on electrical box cover)
MODELS SL585 AND SL595 ARE FOR VEHICULAR
PASSAGE GATES ONLY AND ARE NOT INTENDED FOR
Installation Date __________________
PEDESTRIAN PASSAGE GATE USE

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain Liftmaster Professional SL595

  • Page 1 HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) MODELS SL585 AND SL595 ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR Installation Date __________________ PEDESTRIAN PASSAGE GATE USE...
  • Page 2: Table Of Contents

    Illustrated Parts - Model SL585 ......34 Flange Nut 5/16"-18 Repair Parts - Model SL595 ......35 PRECAUCIÓN Flange Nut 3/8"-16...
  • Page 3: Operator Dimensions And Horsepower Chart

    Maximum Cantilever Gate Width – 40 ft. (12.2 m) Maximum Overhead Roller Gate Width – 75 ft. (22.9 m) Maximum V-Track Gate Width – 55 ft. (16.8 m) MODEL SL595 • 1/2 HP Motor Maximum Gate Speed – 12"/sec. (30.5 cm/sec) Maximum Gate Weight –...
  • Page 4: Ul325 Model Classifications

    U L 3 2 5 M O D E L C L A S S I F I C A T I O N S CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
  • Page 5: Safety Installation Information

    S A F E T Y I N S T A L L A T I O N I N F O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 6: Suggested Entrapment Protection Device Locations

    S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C A T I O N S GATE SYSTEM (MASTER/SECOND SLIDE GATE) Open Edge...
  • Page 7: Safety Precautions For Open Roller Gates

    SAFETY PRECAUTIONS FOR OPEN ROLLER GATES Gate Edge on Fence Gate Edge on Post for Open Direction Gate Edge on Rear of Gate for Leading Edge of Gate WARNING WARNING WARNING Open Direction for Close Direction • Injuries occur when people get their hands or feet caught CAUTION WARNING Photo Beam for...
  • Page 8: Wiring

    W I R I N G WARNING WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you install an optional reversing edge BEFORE proceeding operator MUST NOT be performed until disconnecting the with the control station installation.
  • Page 9: Installation

    I N S T A L L A T I O N PAD MOUNTING (SL585 ONLY) Figure 1 RETRO-FIT INSTALLATION The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can be unbolted and reversed to ‘angle in’.
  • Page 10: Post Mounting (Sl585 & Sl595)

    POST MOUNTING (SL585 AND SL595) RETRO-FIT INSTALLATION Figure 1 The operators come from the factory configured to mount to an inside the frame post mount dimension of 26" (66 cm) (outside to outside of posts). The frame comes slotted to accommodate posts 24 1/8"...
  • Page 11: Install Gate Bracket And Drive Chain

    WARNING WARNING INSTALL GATE BRACKET AND DRIVE CHAIN CAUTION CAUTION WARNING Figure 1 “Outside” Gate To prevent damage to the operator or gate, DO NOT drive the “Inside” limit (nuts) actuators on the shaft past their normal positions. 1. Mount gate brackets to the vertical front and rear posts of the gate (Figure 1).
  • Page 12: Available Conduit Access For The Electrical Box

    Then reverse any two of the three power leads. MANUAL DISCONNECT MODEL SL585 MODEL SL595 DISENGAGEMENT: Rotate disconnect handle 90˚ to DISENGAGEMENT: Open the hinged door and pull the disengage.
  • Page 13: Adjustment

    A D J U S T M E N T LIMIT SWITCH ADJUSTMENT WARNING WARNING NOTE: Make sure the limit nuts are positioned between the limit switch actuators before proceeding with adjustments. To reduce the risk of SEVERE INJURY or DEATH: CAUTION 1.
  • Page 14: Install Vent Plug

    INSTALL VENT PLUG 1. Disconnect power. 2. Remove the pin from the vented plug. 3. Reconnect power. MODEL SL595 MODEL SL585 UL325 ENTRAPMENT PROTECTION GL Board Force Control PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Force Control Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force.
  • Page 15: Ul325 Entrapment Protection

    UL325 ENTRAPMENT PROTECTION (CONTINUED) EDGE/PHOTO OPEN EDGE/PHOTO CLOSE This switch (S2-3) selects edge or photo sensor for the gate This switch (S2-4) selects edge or photo sensor for the gate opening protection input. closing protection input. PHOTO OPEN PHOTO CLOSE Open Photo Eye (Pause): When the Close Photo Eye (Reverse): When the control board is configured for photo...
  • Page 16: Program Settings

    PROGRAM SETTINGS (DIP SWITCH S1) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position. TIMER TO CLOSE TIMER TO CLOSE ENABLE This switch enables the auto close timer. The timer to close feature works in conjunction with the potentiometer located on Max = 180 sec the board.
  • Page 17: Control Connection Diagrams

    CONTROL CONNECTION DIAGRAMS Accessory Terminal Block Accessory Terminal Block 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 24VAC Accessory Power May Be Found On These Terminals 24Vac Soft Open Input (N.O.) Close Override Control Control Board...
  • Page 18: Avertissement

    RADIO RECEIVER All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon UL325, and include recommendations for significant increase in safety. We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions shipped with optional control devices for mounting, wiring, programming and adjustment.
  • Page 19: Accessory Wiring

    PROGRAMMING THE REMOTE TO THE RECEIVER FIGURE 2 1. Pry open the front panel of receiver case with a coin or a screwdriver. Re-connect power to operator (Figure 3). CONSTANT MOMENTARY Jumper Jumper OPERATION OPERATION 2. Press and release the "learn" button on the receiver. The learn Output Output indicator light will glow steadily for 30 seconds.
  • Page 20 ACCESSORY WIRING (CONTINUED) Open Override Control Input Terminals 7 & 5 (Com) - Hard Open Override Control Input 3 4 5 6 7 8 These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. N.O.
  • Page 21: Earth Ground Rod Installation

    EARTH GROUND ROD INSTALLATION WARNING WARNING Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from To AVOID damaging gas, power or other underground utility which to dissipate its energy safely into the earth. CAUTION lines, contact underground utility locating companies Without this path, the intense energy generated by lightning could...
  • Page 22: Sequenced Access Management System

    SEQUENCED ACCESS MANAGEMENT SYSTEM (SAMS) The Sequenced Access Management System or SAMS allows the customer more control when managing vehicular entrances to areas such as apartment complexes, businesses and gated communities. The basic concept of the system is that traffic is controlled by two gates installed in tandem, a fast moving gate such as a barrier gate operator and a slower moving more secure or ornamental gate such as a single or pair of slide/swing gate operator.
  • Page 23: Operation And Maintenance

    O P E R A T I O N A N D M A I N T E N A N C E WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTRUCTIONS. 5.
  • Page 24: Solenoid Actuated Brake

    SOLENOID ACTUATED BRAKE WARNING WARNING The brake minimizes over-travel caused by gate coasting. An added feature of the brake is to assist in preventing back driving To avoid SERIOUS PERSONAL INJURY or DEATH disconnect of the gate. The brake is spring-applied whenever the motor is not electric power BEFORE performing ANY adjustments.
  • Page 25: Control Board Programming And Features

    CONTROL BOARD PROGRAMMING AND FEATURES (CONTINUED) FORCE CONTROL LED Code Diagnostic Meaning Cleared By Flashed Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without Normal operation applying an unreasonable amount of force.
  • Page 26: Troubleshooting

    T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE OPERATOR FAILS TO RUN 1) Improper wired stop control ➤ Check the green LED (D17) on control board. If the green LED is off, check to make sure a stop control has been installed across terminals TB1-3 and TB1-5 of the terminal strip.
  • Page 27: Troubleshooting

    T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE MASTER OR SECOND ➤ 1) Failure to cycle power after setup The power to each unit must be cycled in order to initiate proper OPERATOR IS NOT master/second communication if the operators were previously in FUNCTIONING PROPERLY...
  • Page 28: Self-Regulating Heater Accessory

    SELF-REGULATING HEATER ACCESSORY The heater kits are thermostatically controlled heaters that are utilized in areas where the temperature has the potential to drop below freezing. The heater is adjusted to 15˚C. To change the setting, rotate the temperature control knob on the heater to a new temperature setting.
  • Page 29: Single Phase Wiring Diagram

    DUAL (WH) (BRN) GATE (RD) (GY) = TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY). EXIT LOOP (BRN) NOTES: 1) Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2) Wire color: 115V black, 208V red, 230V orange.
  • Page 30: Single Phase Schematic

    120v black, 208v red, 230v orange, 460v purple, 575v grey. 4. Terminal designations shown for 115v. Terminal block in limit switch enclosure (SL595 only). (GL CONTROL BOARD) 6. For single phase 115v operation, there is an additional white wire from contactor A2 to contactor B4 and the black wire from the transformer to contactor B4 goes to B6.
  • Page 31: Three Phase Wiring Diagram

    GATE (RD) (GY) EXIT LOOP = TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY). (BRN) NOTES: 1) Transformer primary voltage is the same as the operator line voltage. Secondary 24V 60VA. 2) Wire color: 208V red, 230V orange, 460V purple, 575V gray.
  • Page 32: Three Phase Schematic

    For reference primary wire colors: 120v black, 208v red, 230v orange, 460v purple, 575v grey Terminal block in limit switch enclosure (SL595 only). 5. Three phase units are equipped with an internal pilot duty thermal overload device or an external line monitoring system.
  • Page 33: Repair Parts

    R E P A I R P A R T S - M O D E L S L 5 8 5 INDIVIDUAL PARTS SERVICE KITS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 22-120 Brake solenoid, 115V 71-B120G Brake kit - 115 Volt models 22-240 Brake solenoid, 230/460V 71-B240G...
  • Page 34: Illustrated Parts - Model Sl585

    I L L U S T R A T E D P A R T S - M O D E L 5 8 5 SL585 ILLUSTRATED PARTS K5 ( K75-34842) K7 (K75-34791) K6 ( K75-34790) K8 (K29-32410) K3 (K75-34828) K9 (K75-18493) K3 (K75-34828) K4 (K75-34824)
  • Page 35: Repair Parts - Model Sl595

    R E P A I R P A R T S - M O D E L S L 5 9 5 INDIVIDUAL PARTS SERVICE KITS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION K20-1050C-2P Motor - models SL595-50-11, 71-B120G Brake kit - 115 Volt models SL595-50-21, SL595-50-81 71-B240G Brake kit - 230/460 Volt models K20-3050C-4P Motor - models SL595-50-23,...
  • Page 36: Illustrated Parts - Model Sl595

    I L L U S T R A T E D P A R T S - M O D E L 5 9 5 SL595 ILLUSTRATED PARTS K7 (K75-18493) K1 (71-B120G) (71-B240G) (71-B575G) K3 (K75-12858) K2 (K75-18618) K6 (K29-32410)
  • Page 37: Electrical Box

    E L E C T R I C A L B O X K1 (K72-34818) SL585 Only For SL595 Limit Box components, see pages 32 and 33 INDIVIDUAL PARTS INDIVIDUAL PARTS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 13-10024...
  • Page 38: Safety Accessories For Secondary Entrapment Protection

    S A F E T Y A C C E S S O R I E S F O R S E C O N D A R Y E N T R A P M E N T P R O T E C T I O N The following devices are acceptable for Safety Accessories for secondary entrapment protection.
  • Page 39: Notes

    N O T E S...
  • Page 40: Warranty Policy And Service

    TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.

This manual is also suitable for:

Liftmaster professional sl585

Table of Contents