Download Print this page
White Rodgers EMERSON BLUE 1F98EZ-1421 Homeowner User Manual
White Rodgers EMERSON BLUE 1F98EZ-1421 Homeowner User Manual

White Rodgers EMERSON BLUE 1F98EZ-1421 Homeowner User Manual

Hide thumbs Also See for EMERSON BLUE 1F98EZ-1421:

Advertisement

RECORD OF THERMOSTAT OPTIONS SELECTED
For your quick reference, below are the options selected by your installing dealer
to optimize your equipment settings and your personal home comfort preferences.
(Contractor to fill in value or check box. N/A = Not Applicable for your equipment or
application.)
Factory Thermostat Options Configuration Menu
Keypad Lockout "PIN" number:______
Program Days Per Week:
7 Program Days
Continuous Backlight:
On
Temperature Offset: _____(0, 1, 2, 3, 4, 5°)
Temperature Display:
°F
Heat High Limit: ______
Cool Low Limit: ______
Beeper:
On
Off (Touch Key Input Confirmation)
Air Filter Maintenance: _____ Hours (System Runtime)
UV Lamp Maintenance: _____ Days
Humidifier Pad Maintenance: _____ Hours (Continuous Clock)
If you need help adjusting the programmed time or temperatures
in your thermostat, please call Homeowner Help Line at 800-284-2925
For All Other Service, Please Call:
Installing Dealer: ______________________________________________________
Phone: ______________________________________________________
Date Installed: ______________________________________________________
Factory
Setting
0/Non-Programmable
Off
Hi (+)
Lo (-)
°C (Fahrenheit/Celsius)
99°
45°
Manual 37-7212A
EMERSON BLUE
Thermostat
Off
7
On
HOMEOWNER USER GUIDE
°F
On
Off
Off
Off
1046
1F98EZ-1421 / 1F98EZ-1441

Advertisement

loading

Summary of Contents for White Rodgers EMERSON BLUE 1F98EZ-1421

  • Page 1 EMERSON BLUE ™ Factory Factory Thermostat Options Configuration Menu Setting Thermostat Keypad Lockout “PIN” number:______ 1F98EZ-1421 / 1F98EZ-1441 Program Days Per Week: 7 Program Days 0/Non-Programmable Continuous Backlight: HOMEOWNER USER GUIDE Temperature Offset: _____(0, 1, 2, 3, 4, 5°) Hi (+) Lo (-) 0°...
  • Page 2 If a voltage spike or a static discharge blanks out the display or causes erratic operation, you can reset the thermostat. new Emerson Blue Thermostat System. To reset the thermostat, touch and the SYSTEM keys at the same time. The thermostat will go blank and then all segments will be displayed momentarily.
  • Page 3: Table Of Contents

    10.When programming is complete and Enter the Heating Program TABLE OF CONTENTS all of the times and temperatures match your desired heating schedule, 1. Touch the Menu key to display ad- touch Run Schedule. The thermostat ditional key choices. TOUCHSCREEN THERMOSTAT DISPLAY OVERVIEW..4 will now run your program.
  • Page 4: Touchscreen Thermostat Display Overview

    3. Touch the Advance Day key until the 5. If you wish to copy this same program TOUCHSCREEN THERMOSTAT DISPLAY OVERVIEW into other days, touch the Copy key day you wish to copy to is flashing and and repeat steps 3 and 4. the day you are copying is on.
  • Page 5 1. Run Schedule touch key to exit used in programming to PROGRAMMING YOUR THERMOSTAT any menu and begin operating the set time and in configuration menu to program. change selections (page 12). 2. Set Time touch key used for setting 9.
  • Page 6 • Battery Location Select temperature offset. Scrolling message will show “TEMPERATURE ADJUSTMENT”. Your thermostat was 2 “AA” alkaline batteries are included accurately calibrated at the factory, in the thermostat to keep time during a however this option allows you to power outage.
  • Page 7: Quick Start Guide

    • Select program days per week. QUICK START GUIDE Scrolling message will show “PRO- GRAM TYPE”. Default is 7 Days to indicate individual day program- Set Current Time and Day ming. It can be changed to 0 Days to indicate no programs will be run. When set for 7 Days, the thermostat •...
  • Page 8: Choose The System Setting

    • Select humidifier pad maintenance Choose the System Mode (Cool, Off, Heat, Em, Auto) reminder. Scrolling message will show “HUMIDIFIER PAD MAINTE- Touch the SYSTEM key to select: NANCE”. Default is OFF. It can be Cool: Cooling is on. changed to a setting from 25 to 1975 hours in increments of 25 hours to Off: Heating and Cooling are off.
  • Page 9: Using Your Thermostat

    SETTING UP YOUR THERMOSTAT OPTIONS USING YOUR THERMOSTAT The Thermostat has comfort and performance options that can be selected and ad- System Operation justed. These options are in the Thermostat Options Configuration Menu. On the Home Screen Display, touch the Menu key to display additional key choices. Touch the SYSTEM key to select the NOTE: thermostat operating mode desired.
  • Page 10 Permanent Temperature Hold Non-Programmable Mode Maintenance Reminder Message The Permanent Temperature Hold If Program days per week is set for 0 A reminder will display in the scrolling feature bypasses the program and allows days (Non-programmable) in the Ther- message area when it is time for ac- you to permanently hold a temperature.

This manual is also suitable for:

Emerson blue 1f98ez-1441