Electrical connection

Prior to making the electric al con-
nection, make sure that:
- The protection fuse and the domes-
tic wire system are suitable to carry
the total electric load of the oven (see
rating plate).
- Your domestic wiring system has an
efficient earth connection in compli-
ance with the rules and laws in force.
- The wall socket or the omnipole
switch used for the electrical con-
nection can easily be reached after
the oven is built in.
The appliance is delivered without an
electric supply cable, therefore, you will
have to fit to it a supply cable with stand-
ard plug, suitable for the total electric
load shown on the rating plate.
The plug is to be inserted into a suit-
able wall socket.
If you require a direct connection to
the electric network (mains), it will be
necessary to fit between the appliance
and the mains an omnipole switch, aith
a minimum gap between contacts of 3
mm. suitable for the required load and
in compliance with rules in force. The
green and yellow ground wire must not
be interrupted by the switch.
The supply cable must in all cases be
laid out in such a way as to ensure that
it does not reach at any given point a
temperature 50°C higher than the am-
bient temperature.
The manufacturer disclaims any li-
ability in case these accident-preventing
rules are not observed.
Suitable power supply cables are the
following types, considering the respec-
tive necessary section of cable.
• H07 RN-F
• H05 RN-F
• H05 RR-F
• H05 VV-F
• H05 V2V2-F (T90)
Connecting the terminal board
The appliance incorporates an eas-
ily accessible 6-pole terminal board
whose jumpers (bridges) are already
pre-set for operation on 400 V three-
phase with neutral wire. In case where
different mains voltage is present, the
jumpers on the terminal board must be
arranged as shown in the diagram.
The ground cable must be con-
nected to terminal
After connecting the supply cable to
the terminal board, secure it with a junc-
tion clamp.
1 2 3 4 5
230V 3~
L1
1 2 3 4 5
230V 1~
L1
1 2 3 4 5
400V 2N~
L1 L2
1 2 3 4 5
400V 3N~
L1 L2 L3 N
. . . . .
Section
of cable
(min.)
L2
L3 PE
4 x 1.5 mm
Section
of cable
(min.)
3 x 2.5 mm
N
PE
Section
of cable
(min.)
4 x 2.5 mm
N
PE
Section
of cable
(min.)
5 x 1.5 mm
PE