Genie H8000-07 Operation And Maintenance Manual page 11

Dc powered screw drive opener complete with intellicode remote control and series ii electronics
Table of Contents

Advertisement

Opener System Self-Diagnostic Troubleshooting
See Status Light on Figure MA-2, page 9)
You See
Problem
1 BLINK,
Motor Drive
Pause
Board
(Repeat)
Interrupt
Normal
operation
restored
If the problem
recurs
Operation not
restored
2 BLINKS,
Controller
Pause
Board
(Repeat)
Interrupt
3 BLINKS,
Opener
Pause
Overheated
(Repeat)
or
Over-cycled
4 BLINKS,
Force Settings
Pause
Incorrect
(Repeat)
5BLINKS,
Safe-T-Beam®
Pause
Malfunction
6 BLINKS,
Wall Console
Pause
does not work •
(Repeat)
7 BLINKS,
Limit Switches •
Pause
not working
(Repeat)
8 BLINKS,
Wall Console
Pause
locked
(Repeat)
The status LED Indicator Light is located under the Lens Cover. The Green LED light will turn ON, then OFF when
power is applied to the Opener . If LED stays ON, have a Genie Factory Authorized Dealer check the Controller
Board, or call Customer Service at 1-800-35-GENIE .
If Safe-T-Beam® problems exists, the door can be closed electrically by holding the Wall Console Button down
until door is fully closed .
The Remote Controls and Wireless Keypad will not work without a working Safe-T-Beam® System.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Reset Opener—unplug (or disconnect power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console .
First Cycle will run at slow speed .
Check door condition . NOTE: This Opener is equipped with an
automatic garage door balance detection system. An improperly
balanced door, damaged or worn counter-balance spring, binding
door hardware or rollers may result in a "ONE-BLINK" signal.
Contact Customer Service for further assistance .
Check door condition .
Have a Genie Factory Authorized Dealer check:
– Fuse on Motor Drive Board .
– Ribbon Cable on Motor Drive Board is properly inserted into
Connector on Controller Board .
Contact Customer service for further service .
Reset Opener — unplug (or disconnect power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console .
Have a Genie Factory Authorized Dealer check that Ribbon Cable on
Motor Board is properly inserted into connector on Controller Board .
Contact Customer Service for further assistance .
Do not unplug or disconnect power from Opener. Wait 10 minutes
for internal clock to provide additional cycles. Cycles are restored
at a rate of 5 cycles per 10 minutes of rest.
Contact Customer Service for further assistance.
Check Force Settings . NOTE: Force Settings are not pre-set at factory. 1 . See page 7 .
Check door condition .
Contact Customer service for further assistance .
Check Safe-T-Beam® Self-diagnostic System . NOTE: Safe-T-Beam®
System must be installed and operational to enable door to close.
Contact Customer Service for further assistance .
Check Wall Console Wiring for shorts, tight Staples, or pinched Wires .
Check Wiring Connections at Power Head and Wall Console .
Contact Customer Service for further assistance .
Check Limit Switch Wire connections to Terminals on Power Head .
Check for shorted or pinched Wires under Limit Switch Brackets .
Contact Customer Service for further assistance .
Vacation Locking Switch on Wall Control is in "Lock" mode .
Unlock switch .
Contact Customer Service for further assistance .
NOTE
What to Do
Reference
See Door
Safety Guide
1 . See page 4 .
2 . See door
Safety Guide
2 . See Door
Safety Guide
See page 13 .
Assembly and
Installation
Poster .
Assembly and
Installation
Poster .
Assembly and
Installation
Poster .
11

Advertisement

Table of Contents
loading

Table of Contents