MAINTENANCE

A Monthly:
• Door springs and door hardware:
– Oil door roller, bearings, and hinges using silicone
lubricant or light oil .
Do not operate door automatically or manually if springs
are broken . Contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE .
• Balance Door .
– Close door .
– Release Magnetic Carriage Assembly from Rail Assembly
by pulling down on Emergency Release Knob .
– Raise door manually 3'- 4' and verify that door stays at
that position . See Check Step 2 on page 4 .
When the door is 3' - 4' above the ground, the door
should stay open . Slight movement is acceptable . If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1-800-35-GENIE.
– Reattach Magnetic Carriage Assembly to Rail Assembly by
pulling the Emergency Release Knob toward Power Head .
– Close door .
• Contact Reverse Test.
– Perform Adjustment 2 on page 8 .
t
RoubleShootiNG
Safe-T-Beam® System Self-Diagnostic Troubleshooting
Source (Red LED)
ON
OFF
OFF
2 BLINKS, Pause
(Repeat)
2 BLINKS, Pause
(Repeat)
3 BLINKS, Pause
(Repeat)
4 BLINKS, Pause
(Repeat)
10
WARNING
NOTE
G
uiDe
Sensor (Green LED)
ON
OFF
ON
ON
OFF
ON
ON
If the door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 7 . If the Opener still
fails, contact a Genie Factory Authorized Dealer for service
or call Customer Service at 1-800-35-GENIE .
B Yearly:
• Wipe off old excess lubricant from Drive Screw .
• Lubricate Drive Screw with Genie Lubricant (GLU-3)
Use ONLY Genie Lubricant (GLU-3) . Other lubricants
may damage the Opener .
FCC AND IC CERTIFIED
All devices comply with Part 15 of the FCC Rules .
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation .
Possible Problem
Normal operation
• Power Head not powered
• Wiring from Power Head bad
• Wiring to Source missing or bad • Check wiring
• Power has been interrupted
• Beam not aligned
• Beam obstructed
• Sensor defective
• Wire to Sensor missing or bad
• Sensor defective
• Sensor receiving interference
• Source not sending pulses
• Source defective
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
WARNING
NOTE
GLU-3
Lubricant
Solution
None required
• Check breakers, fuses, plugs
• Check wiring for obvious shorts
• Remove power and reapply
• Check Source, Sensor alignment
• Check for obstruction
• Contact Customer Service
• Check wiring
• Contact Customer Service
• Determine source of interference
• Contact Customer Service
• Contact Customer Service
• Contact Customer Service