Genie Excelerator 3531835447 User Manual page 27

Genie garage door opener user manual
Hide thumbs Also See for Excelerator 3531835447:
Table of Contents

Advertisement

See
Status
Light
on Figure38,
page
22)
You See
1 BLINK,
Pause
(Repeat)
2 BLINKS,
Pause
(Repeat)
3 BLINKS,
Pause
(Repeat)
4 BLINKS,
Pause
(Repeat)
SBLINKS,
Pause
6 BLINKS,
Pause
7 BLINKS,
Pause
Problem
Motor Drive
Board
Normal
operation
restored
If the problem
recurs
Operation
not
restored
Controller
Board
Interrupt
Opener
Overheated
or
Force Settings
Incorrect
Safe-T-Beam ®
Malfunction
Wall Console
does not work
Limit Switches
not working
What to Do
.
Reset Opener--unplug
(or disconnect
power), wait 5 seconds, plug
back in (reapply power), and activate from Wall Console.
.
First Cycle will run at slow speed.
Reference
.
Check door condition. NOTE:This
Opener is equipped
with an
automatic
garage door balance detection
system. An improperly
balanced door, damaged
or worn counter-balance
spring, binding
door hardware
or rollers may result in a "ONE-BLINK"
signal,
Contact Customer Service for further assistance.
.
Checkdoor
condition.
.
Have a Genie Factory Authorized
Dealer check:
-
Fuse on Motor Drive Board.
-
Ribbon Cable on Motor Drive Board is properly
inserted into
Connector
on Controller
Board.
.
Contact Customer service for further
service.
.
Reset Opener -- unplug
(or disconnect
power), wait S seconds, plug
back in (reapply power), and activate from Wall Console.
.
Have a Genie Factory Authorized
Dealer check that Ribbon Cable on
Motor Board is properly inserted into connector
on Controller
Board.
.
Contact Customer Service for further assistance.
.
Do not unplug or disconnect
power from Opener.Wait
10 minutes
for internal
clock to provide additional
cycles. Cycles are restored
at a rate of S cycles per 10 minutes
of rest.
.
Check Force Settings. NOTE: Force Settings are not pre-set at factory.
.
Checkdoor
condition.
.
Contact Customer service for further assistance.
.
Check Safe-T-Beam ® Self-diagnostic
System. NOTE: Safe-T-Beam ®
System must be installed and operational
to enable door to close,
Contact Customer Service for further assistance.
.
Check Wall Console Wiring for shorts, tight Staples, or pinched Wires.
.
Check Wiring Connections
at Power Head and Wall Console.
Contact Customer Service for further assistance
.
Check Limit Switch Wire connections
to Terminals on Power Head.
.
Check for shorted or pinched Wires under Limit Switch Brackets.
.
Contact Customer Service for further assistance.
.
Vacation Locking Switch on Wall Control is in"Lock" mode.
Unlock switch.
.
Contact Customer Service for further assistance.
See Door
Safety Guide
1. See page
3.
2. See door
Safety
Guide
1. See page 20.
2. See Door
See page 16.
See page 18.
See page 20.
8 BLINKS,
Wall Console
See page 18
Pause
locked
(Repeat)
NOTE
The status LED Indicator Light is located under the Lens Cover.The Green LED light will turn ON, then OFF when
power is applied to the Opener. If LED stays ON, have a Genie Factory Authorized Dealer check the Controller
Board, or call Customer Service at 1-800-35-GENIE.
If Safe-T-Beam® problems exists, the door can be closed electrically by holding the Wall Console Button down
until door is fully closed.
The Remote Controls and Wireless Keypad will not work without a working Safe-T-Beam® System.