4.12 SERVICE SCHEDULE

be performed by the nearest Generac/Guardian Authorized Dealer.
SYSTEM/COMPONENT
X = Action
R = Replace/Adjust as Needed
* = Notify Dealer
if Repair is Needed.
FUEL
Fuel lines and connections*
LUBRICATION
Oil level
Oil
Oil filter
Oil line leakage*
COOLING
Engine cooling system*
Coolant
Enclosure louvers
EXHAUST
Exhaust system
Retorque Exhaust Manifold*
BATTERY
Charge and condition
FAN BELT
Tension and condition*
ENGINE
Retorque cylinder head*
Retorque intake manifold*
Starter motor*
DC alternator*
Air cleaner*
Compression*
Valve clearance*
Governor*
Safety devices*
Spark plugs
Ignition system*
GENERAL
Overall condition
Exercise system
COMPLETE TUNE-UP*
ATTENTION: It is recommended that all service work
Inspect
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
TO BE COMPLETED BY A GENERAC/
GUARDIAN AUTHORIZED DEALER
Section 4 — Maintenance
Guardian Liquid-cooled 40 kW Generator
PROCEDURE
Change
Clean
X
X
X
R
R
R
R
R
R
R
R
R
R
FREQUENCY
W = Weekly
M = Monthly
Y = Yearly
H = Hours
EVERY 3 M
M
FIRST 30 H,
EVERY 150 H / 6 M
FIRST 9 H,
EVERY 150 H / 6 M
100 H
M
Y
X
W
EVERY 3 M
FIRST 100 H AND
EVERY 800 H
X
EVERY 3 M
EVERY 3 M
FIRST 100 H AND
EVERY 800 H
FIRST 100 H AND
EVERY 800 H
EVERY 500 H
EVERY 500 H AND Y
EVERY 500 H
EVERY 800 H
EVERY 800 H
Y
EVERY 6 M
500 H AND Y
EVERY 3 M
X
M
W
Y