Instructions for the installer
Before making the electric connection, make sure of the safety of the earth.
Make sure that the fuse and the home wiring system are able to withstand the appliance load.
The yellow/green earth cable must not be interrupted at any point.
The electric cable must not come into contact with parts whose temperature is more than 50°C
higher than room temperature.
12.2.1 Electric power cable section
According to the type of power supply, use a cable that conforms to the following diagram.
Running at 400V3N~ (models connected according to DIAGRAM
"A"): use a pentapolar cable type H05RR-F/H05RN-F (cable
2
measuring 5 x 2.5 mm
).
Running at 230V3~ (models connected according to DIAGRAM
"C" but commutated by the installer according to DIAGRAM "B"):
use a tetrapolar cable type H05RR-F/H05RN-F (cable measuring 4 x 4
2
mm
).
Running at 230V1N~ (models connected according to DIAGRAM
"C"): up to 2.9 kW use a tripolar cable type H05RR-F/H05RN-F
(cable measuring 3 x 1.5 mm
tripolar cable type H05RR-F/H05RN-F (cable measuring 3 x 2.5 mm
The end to be connected to the appliance must have the earth wire
(yellow-green) at least 20 mm longer.
12.2.2 Type of power supply
It is possible to obtain different connections according to the mains voltage by connecting the
mains cable to the terminal board as shown in the following diagrams.
According to the model, consult the table "C
DIAGRAM "A"
COOKER 4 BURNERS (2 OVENS) + FRY-TOP
COOKER VITROCERAMIC HOB (2 OVENS) (5 HEATING ELEMENTS)
M
ODELS CONNECTED ACCORDING TO DIAGRAM
"B".
2
); between 2.9 kW and 5.4 kW use a
ONNECTION TO THE TERMINAL BOARD
DIAGRAM "B"
CONNECTION TO THE TERMINAL BOARD
MODEL
"A"
CAN BE COMMUTATED BY THE INSTALLER ACCORDING TO DIAGRAM
2
).
".
DIAGRAM "C"
POWER kW
POWER SUPPLY
6,3
DIAGRAM "C"
13,7
DIAGRAM "A"
27