Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures
the data link can support.
Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-
485 standard, no more than 32 fixtures should be connected on one data link. Connecting
more than 32 fixtures on one serial data link without the use of a DMX optically-isolated
splitter may result in deterioration of the digital DMX signal.

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX
cables directly from a dealer/distributor or construct your own cable. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less prone to
electromagnetic interference.

DMX Data Cable

Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications.
Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must
have the following characteristics:
Type:
Maximum capacitance between conductors:
Maximum capacitance between conductor and shield:
Maximum resistance:
Nominal impedance:

Cable Connectors

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
INPUT
Do not allow contact between the common and the fixture's chassis ground. Grounding the common can cause a
Double Derby™ X User Manual
Maximum recommended serial data link distance: 500 m (1640 ft)
Maximum recommended number of fixtures on a serial data link: 32
COMMON
1
DMX +
3
2
-
DMX
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify
correct polarity and to make sure the pins are not grounded or shorted to the shield or each
other.
shielded, 2-conductor twisted pair
1
3
2
1
OUTPUT
3
2
To avoid signal transmission
problems and interference, it is
always advisable to connect a DMX
signal terminator.
8
30 pF/ft
55 pF/ft
20 ohms/1000 ft
100 ~ 140 ohms
Resistance 120 ohm
¼ W between pin 2
(DMX -) and pin 3
(DMX +) on the
output of the last
fixture.
7/24/2009 4:32 PM