Connecting To The Electricity Supply - Electrolux Insight EIKG6046 Instruction Booklet

Hide thumbs Also See for Insight EIKG6046:
Table of Contents

Advertisement

CONNECTING TO THE ELECTRICITY
SUPPLY
Warning: This appliance must be earthed.
Do not earth this appliance to the gas
supply piping.
Connect to 230-240 A.C supply only.
Connection to the electricity supply should be made
via a properly earthed, readily accessible wall
socket. Which is adjacent to, but not directly above
and not more than 1.7m away from the appliance
and capable of electrical isolation. The cooker point
should be within 1.7m of the appliance to make it
accessible to switch off the appliance in case of
emergency. The mains lead should be routed so
that it cannot touch hot parts of the cooker i.e. the
back panel above a height of 650mm from the floor.
Should this plug not fit the socket outlet in your
home it should be cut off and replaced with a
suitable plug as outlined below.
If the supply cord is damaged, it must be replaced.
Please contact your local Service Force Centre.
If the moulded plug is cut from the cable for any
reason it must be destroyed or disposed of
safely, as protruding wires will be an electrical
shock hazard.
If the fitted plug is removed.
The flexible mains lead must be correctly connected
as below to three pin plug of not less than 13amp
capacity. If a B.S. 1363 fused plug is used, it must
be fitted with a 3 amp fuse which is approved to B.S.
1362.
Important: The wires in the mains lead fitted to the
appliance are coloured in accordance with the
following code.
GREEN AND YELLOW -EARTH
BLUE
BROWN
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:-
The wire which is coloured green and yellow must
be connected to the terminals in the plug which is
marked with the letter E or by the earth symbol (
or coloured green or green and yellow. The wire
which is coloured blue, must be connected to the
terminal which is marked with the letter N or
coloured black. The wire which is coloured brown,
must be connected to the terminal, which is marked
with the letter L or coloured red.
Ensure that the cable does not become trapped
when pushing the appliance into position.
If a moulded plug is fitted.
In the event of replacing a fuse in the plug supplied a
3 amp ASTA approved fuse to B.S. 1362 must be
fitted.
:
Note
The fuse cover must be refitted when
changing the fuse. In the event of losing the fuse
cover the plug must not be used until a replacement
fuse cover has been obtained and fitted.
-NEUTRAL
-LIVE
)
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Insight eikg6047

Table of Contents