Poor Scanning Quality - Sharp AR-5516 Operation Manual

Digital multifunctional system
Hide thumbs Also See for AR-5516:
Table of Contents

Advertisement

TROUBLESHOOTING
Problem

Poor scanning quality.

70
Cause and solution
The document glass or the underside of the document
cover/SPF/RSPF is dirty.
→ Clean regularly.
Original smudged or blotchy.
→ Use a clean original.
You have not specified a suitable resolution.
→ Make sure that the resolution setting in the scanner driver is
appropriate for the original.
You are scanning a large area (for example an entire A3)
at high resolution.
→ If you attempt to scan a large area at high resolution and there is
insufficient memory in the machine to hold the scanned data,
scanning will take place at a lower resolution and the scanner
driver will enhance the data to make up for the lower resolution.
However, the quality of the enhanced image will not be as high as
if scanning took place at the higher resolution. Use a lower
resolution setting, or scan a smaller area.
You have not specified a suitable value for the "B/W
Threshold" setting.
→ If you are scanning with a TWAIN-compliant application, make
sure that a suitable value is specified for the "B/W Threshold"
setting. A larger threshold value makes your output darker, while
a small threshold value makes it lighter. To adjust the threshold
automatically, click the "Auto Threshold" button on the "Image"
tab of the "Professional" screen.
The brightness and contrast settings are not suitable.
→ If you are scanning with a TWAIN-compliant application and the
resulting image has unsuitable brightness or contrast (for
example it is too bright), click the "Auto Brightness/Contrast
Adjustment" button on the "Colour" tab of the "Professional"
screen. Click the "Brightness/Contrast" button to adjust the
brightness and the contrast while viewing the scanned output
image on the screen. If you are scanning with a WIA-compliant
application or the "Scanner and Camera Wizard", click "Adjust the
quality of the scanned picture" or the "Custom settings" button,
and adjust the brightness and contrast in the screen that appears.
The original is not placed face up in the SPF/RSPF or face
down on the document glass.
→ Place the original face up in the SPF/RSPF or face down on the
document glass.
The original was not placed in the correct position.
→ Place the original correctly.
Page
83
15, 16
15, 16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-5520Ar-5516dAr-5520d

Table of Contents