SPECIFICATIONS
Model:
Manufacturer:
Sample FCC Part 15 Registration:
(Refer to the label on the Base Unit for the FCC
Registration Number.)
1. Do not run station cable in parallel with the AC
source, telex or computer, etc. If the cables are near
cable runs to those devices, use shielded cable with
grounded shields or install the cable in conduit.
2. When cables must be run on the floor, use cable
protectors.
3. The cable run must be a dedicated, isolated cable
pair.
4. Use 1-pair twisted 24 AWG cable (2-pair cable if
installing an optional desk phone), cable run length
not to exceed 2,000 feet.
3-4
FCC Registration Information
Cabling Requirements
900i
NEC Infrontia, Inc.
AMWUD905