Something Not Working

Before contacting your local Service Force Centre check the following point:
Problem
" " is displayed in the temperature
display.
Audible alarm + flashing red warning
lamp. (It is too warm inside the freezer.)
It is too warm inside the freezer.
It is too cold inside the freezer.
Too much frost and ice are produced.
The compressor operates continuously.
The cabinet does not operate at all.
Cooling or interior light does not
operate. No indicator lamps light.
Sound level in cabinet is too high.
Possible cause / Remedy
Please contact your local Electrolux Service Force Centre
Switch off the audible alarm by pressing the alarm off button.
The audible alarm could have been triggered by:
The cabinet having been recently switched on and the
temperature still being too high. See the chapter "Switching on
and setting the temperature".
The door may have been open for so long that the `door open'
alarm was triggered.
Set a lower temperature.
Make sure that the door is completely closed and that the
insulating strip is complete and clean.
If warm food products have been put inside the freezer, wait for
a couple of hours and then check the temperature again.
Distribute the food products to allow cold air to circulate
around them.
Set a warmer temperature.
Fast Freeze could have been switched on.
The temperature display shows the highest temperature inside
the cabinet. Thus a difference between the temperature
indicated on the display and the (average) temperature
measured in another way is normal.
Make sure that the door is completely closed and that the
insulating strip is complete and clean.
Set a warmer temperature.
Make sure that the door is completely closed and that the
insulating strip is complete and clean.
The temperature where the cabinet is placed is above normal
room temperature.
The cabinet is not switched on.
Power does not reach the cabinet. (Try connecting another
electrical device to the power outlet.)
The fuse has blown.
The power plug is not properly connected.
The refrigerating system will always produce some sounds. A
pulsing sound is heard when coolant is pumped inside the
cooling pipes. A ticking sound from the thermostat can be
heard when the compressor switches on and off. The sound
level varies depending on the operation of the cabinet.
If you feel the sound level is incorrect:
Make sure the pipes at the back of the cabinet not touch each
other. Carefully bend them if they do.
If the cushion spacers (between the cabinet wall and pipes)
come loose, put them back in place again.
Carefully follow the instructions in the chapter "Installing the
cabinet".