Installation instructions

Safety information

Warning! The minimum safety spacing "D"
between cooking surface and hood is 500 mm
for electrical cookers and 700 mm for gas
cookers.
The unit must be disconnected from the power
supply for servicing purposes. Withdraw the
mains plug.
The general guidelines for operation of
electrical appliances, the regulations of the
relevant electricity supply company and the
information contained in these installation
instructions must be followed exactly.

Exhaust system

The steam and fumes produced above the cooker are
cleaned in the fat filters and taken outside through an
exhaust pipe.
Warning! The exhaust air must not be taken
to a smoke-stack if exhausts from other
appliances are present, which are not
electrically operated.
Sufficient ventilation must be ensured if steam
exhaust
and
electrically are used together.
The cantonal fire prevention regulations must
also be observed.
Requirements for the exhaust
pipe
Diameter 125 mm
Smooth-walled exhaust pipe
Optimum laying with as little air resistance as
possible
Caution! The air flow declines if these
requirements are not observed.
12
appliances
not
operated
125
0-50
100
495
598
600
Air flow
400
300
200
100
0
200
0
100
m3/h
125
max. 140
201
319
A = appliance
N = niche
Level 3
Level 2
Level 1
600
300
400
500