2 TROUBLESHOOTING FOR COPYING

Copying Problems

See the table below when you have a problem in operating copy function or have an unexpected copy output.
Problem Description
Functions cannot be set.
Copying stops during scanning of
the originals. (The message "The
number of originals exceeds the
limits Will you print out stored
originals?" appears.)
Copying stops during scanning of
the originals. (The message "Not
enough Work Space to store
originals Will you print out stored
originals?" appears.)
Copied image is too light.
Copied image is too dark.
Copied image has stains.
Copied image has stains.
Copy image is skewed.
Copied image is partially missing. The size or orientation of the copy
72
Copying Problems
Cause
Another function that is unavailable
for the combination has already been
set.
The number of scanned pages has
reached the maximum.
No available internal memory
remains.
No toner is left.
Copy density is set too light.
Copy density is set too dark.
The Original Cover or the Reversing
Automatic Document Feeder is not
fully lowered.
The original glass, platen sheet,
scanning area and guide are stained.
The copy density is set too dark.
A transparent original such as a
transparency or tracing paper is being
used.
The separation fingers in the fuser
unit are dirty.
The original is sent from the
Reversing Automatic Document
Feeder at a skew.
paper and that of the original are not
consistent. The reduction ratio is not
properly set.
The binding margin is too wide.
The original is larger than the
printable area.
Corrective Action
Some functions cannot be combined.
For details, refer to Chapter 8 of the Copying Guide.
To copy the scanned images, press [YES]. To cancel,
press [NO].
To copy the scanned images, press [YES]. To cancel,
press [NO].
The message "Install new Black (Cyan, Magenta or
Yellow) cartridge" appears when no toner is left. Replace
the toner cartridge of the color the message indicates.
 P.51 "Replacing a Toner Cartridge"
Darken the density manually or try the automatic density
mode.
Lighten the density manually or try the automatic density
mode.
Lower it fully to block outside light.
Clean them.
 P.120 "Regular Maintenance"
Lighten the density manually or try the automatic density
mode.
To copy a transparent original clearly, put a sheet of blank,
white paper behind the original. Make sure that the paper
is large enough to cover the original.
When paper is placed on the bypass tray to make copies,
set its size.
Replace the original while aligning the side guides of the
Reversing Automatic Document Feeder to its width so that
it will be placed straight.
Fit the copy paper size to the original or set the reduction
ratio for the copy paper.
Set the binding margin width to fully cover the original.
For details, refer to Chapter 4 of the Copying Guide.
The outside part of the printable area cannot be copied.
The Full Image function enables you to copy the whole
image of the original in the 95 - 99% reduction ratio.