1.TROUBLESHOOTING FOR THE HARDWARE
5
Fit the new staple cartridge.
Insert each cartridge until it is fixed with a click.
6
Unlock the stapler of the saddle stitch unit by pulling
its handle toward you, and lower the stapler to its
original position.
7
Slowly insert the saddle stitch unit into the finisher.
8
Make sure that the following two requirements are met before test stapling:
The Saddle Stitch Finisher is securely attached on the equipment.
A3, B4, A4-R, LD, or LT-R paper is loaded in the drawer.
When the message "Check staple cartridge in the Saddle Stitch unit" is displayed, this step is unnecessary.
Proceed to step 9.
9
Close the lower front cover of the finisher.
When the message "READY (CHECK STAPLER)" is displayed, test stapling starts automatically.
Test stapling is necessary to prevent void stapling. Note that the test stapling starts automatically when the two
requirements in step 8 are met with the lower cover of the Saddle Stitch Finisher closed. If the test stapling does
not start, make sure to check the two requirements again. Then open and again close the lower cover of the
Saddle Stitch Finisher.