Care And Cleaning Cartridge Replacement; Procedure, Including Sanitization - GE GXRV10ABL01 Owner's Manual And Installation

Reverse osmosis
Hide thumbs Also See for GXRV10ABL01:
Table of Contents

Advertisement

Available languages

Available languages

Care and cleaning—RO cartridge replacement procedure,
including sanitization.
Reverse Osmosis Cartridge Replacement
NOTE: When replacing the Reverse Osmosis
cartridge, also install a new flow control and screen.
See the Flow Control and Screen section.
If the Reverse Osmosis Filtration system is
connected to your icemaker YOU MUST turn off the
icemaker by raising the feeler arm before servicing
the filter, changing the filters or purging the
filtration system. Four hours after servicing your
unit, lower the feeler arm to resume icemaking.
Be sure you clean your hands with anti-bacterial
soap before handling inner parts of the system.
Turn off the water supply valve to the Reverse
1
Osmosis system (turn clockwise) and open the
RO water faucet. Allow the system to drain
completely (this takes several minutes).
CAUTION: Failure to close the water supply valve
will cause water to spray or run when sumps
are removed.
Pull the Reverse Osmosis system out away
2
from cabinet. Leave tubing connected. Place
a dry towel under the Reverse Osmosis unit.
Unscrew inlet cover cap to open Reverse
3
Osmosis housing.
Use pliers to pull the cartridge from the
4
housing and discard the cartridge.
8
Sanitize the system. Go to Filter Change
5
Procedure, including sanitization section.
Complete Steps 5 – 9. However, place filters in
clean plastic bag and reinstall them at Step 9.
1/4" tubing
Screen
Check
valve tee
Drain elbow
Compression
nut
Flow control

Advertisement

Table of Contents
loading

Table of Contents