Replacing The Heat Sink And Fan Assembly - Lenovo ThinkServer TS440 User Manual

Machine types: 70al, 70am, 70an, and 70aq
Hide thumbs Also See for ThinkServer TS440:
Table of Contents

Advertisement

6. Touch the static-protective package that contains the new rear system fan to any unpainted surface on
the outside of the server. Then, remove the new rear system fan from the package.
7. Position the new rear system fan, which has four new rubber mounts attached, on the chassis so that
the four new rubber mounts are aligned with the corresponding holes in the chassis. Push the rubber
mounts through the holes, and then pull on the tips of the rubber mounts from the other side of the
chassis until the rear system fan is secured in place.
Figure 87. Installing the rear system fan
8. Connect the new rear system fan cable to the rear system fan connector on the system board. See
"System board components" on page 37.
9. If you are instructed to return the old rear system fan, follow all packaging instructions and use any
packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to "Completing the parts replacement" on page 141.

Replacing the heat sink and fan assembly

Attention: Do not open your server or attempt any repair before reading and understanding "Safety information"
on page iii and "Guidelines" on page 63.
This topic provides instructions on how to replace the heat sink and fan assembly.
132
ThinkServer TS440 User Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents