Chapter 6 Daily Care
6 When you press the [Scan/Enter] button, the feed/eject rollers
rotate a certain amount.
When you press the [Scan/Enter] button,
the feed/eject rollers rotate at the same
time. Be careful not to touch the rollers with
your hand while they are rotating.
7 Put a piece of cloth moistened with Cleaner F1 or a sheet of
Cleaning Wipe against the roller surface, and wipe horizontally.
Wipe off any dirt or dust on the surface by pressing the [Scan/
Enter] button to rotate the rollers.
Make sure that it is wiped properly because black residue on the
roller will affect the feeding performance.
As a guideline, pressing the [Scan/Enter] button seven times will
rotate the feed/eject rollers one revolution.
[Scan/Enter] button
4
Close the ADF.
For details, refer to
"1.4 Opening/Closing the ADF" (page 27).
Be careful not to have your fingers caught
when closing the ADF.
ATTENTION
Confirm that the ADF is closed properly. Otherwise, the document
may not be fed into the ADF.
5
Reset the cleaning counter.
Reset the counter by performing one of the following actions:
Reset the counter in [4: Consumable counters] on the [Settings
Menu] screen of the operator panel.
For details, refer to
"4.2 Settings Menu" (page
Reset the counter in the Software Operation Panel.
For details, refer to
"Resetting the sheet counters" (page