Snmp; A.1.2 Snmp - Fujitsu ETERNUS DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.1 Message Format
A.1.2

SNMP

The ETERNUS DX Disk storage system supports three versions of SNMP: SNMPv1, SNMPv2c,
and SNMPv3.
SNMPv3 supports MD5 and SHA as the authentication method and DES as the encryption
method.
To monitor the ETERNUS DX Disk storage system using SNMP Trap, software that can receive
and analyze SNMP Traps must be used on the network.
This section describes the type and the notification format of Traps. For details on the messages
that are notified by SNMP Trap, refer to
For the display contents of events (SNMP Traps) when using the server management software
"ServerView Operation Manager" for monitoring the ETERNUS DX Disk storage system, refer to
"Appendix B Event (SNMP Trap) Display When Using ServerView Operation Manager" (page
121).
Trap type
There are two types of Traps: Generic Trap (standard Trap) and Specific Trap (extended Trap).
Generic Trap is a Trap that is defined by the SNMP protocol. Specific Trap is a Trap that has
been created specifically for the ETERNUS DX Disk storage system. The ETERNUS DX Disk
storage system supports the following types of Traps:
Generic Trap (standard Trap)
Trap No.
Specific Trap (extended Trap)
Trap No.
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
Name
0
coldStart
4
authenticationFailure
6
enterpriseSpecific
Name
2
fjdarye101ItemFault
5
fjdarye101ItemWarning
6
fjdarye101SensorStatusChange
7
fjdarye101MaintenanceRequired
9
fjdarye101Information
22
fjdarye101ItemFaultToNormal
25
fjdarye101ItemWarningToNormal
26
fjdarye101SensorStatusChangeToNormal
Copyright 2013 FUJITSU LIMITED
"A.2 Message List" (page
Description
For an ETERNUS DX Disk storage system, this Trap is
sent when the controller starts up and restarts and
when SNMP is set.
An unauthorized access occurred.
Extended Trap
This Trap is sent to notify that a component fails
or degrades.
This Trap is sent to notify that a component
requires preventive maintenance.
This Trap is sent to notify that a temperature
error is detected.
This Trap is sent to notify that an event requires
maintenance or preventive maintenance.
This Trap is sent to notify Information-level
events.
This Trap is sent to notify that an event notified
by Trap No. 2 returns to normal status.
This Trap is sent to notify that an event notified
by Trap No. 5 returns to normal status.
This Trap is sent to notify that an event notified
by Trap No. 6 returns to normal status.
90
95).
Description
P3AM-5512-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents