Fujitsu ETERNUS DX60 S2 User Manual page 117

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
When the event type is "R"
The following messages are sent when a normal state is restored for Error or Warning level
events.
Event type
and event
R 06SSMM00 25
R 90SSddnn
R D2SSdd0n 22
R DASSdd00 26
R DBSSdd00 26
*1:
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
(*1)
TrapItemID
code
No.
0600MM00 0
25
9000ddnn
0
D200dd0n
-
DA00dd00 0
DB00dd00 0
This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26.
Copyright 2013 FUJITSU LIMITED
Upper: Message
Lower: Description
Controller Module#m(zz xxHz) BE Expander Normal
<pppppppppppp ssssssssss rrrrr>
Normal status is restored for a CM BE Expander
error.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
Expander DE#dd/EXP#n Normal <pppppppppppp
ssssssssss rrrrr>
Normal status is restored for a DE Expander error.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
nn: Port number (00 – 01)
n: EXP number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
Power Supply Unit DE#dd/PSU#n Normal
<pppppppppppp ssssssssss rrrr>
Normal status is restored for a PSU error.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
n: PSU number (0 – 1)
pp...: Component number
ss...: Serial number
rr...: Version
DE OUT TEMP Normal
Normal status is restored for a CE exhaust
temperature error or DE exhaust temperature error.
dd: DE-ID ("00" for a controller enclosure)
DE IN TEMP Normal
Normal status is restored for a CE intake
temperature error or DE intake temperature error.
dd: DE-ID ("00" for a controller enclosure)
117
Remarks
These messages
are notified when
"Recovery from
Error" is enabled for
Warning Level in the
event notification
setting.
They are not notified
during maintenance
operations.
P3AM-5512-05ENZ0

Hide quick links:

Advertisement

Table of Contents
loading